KTI Networks KS-801 Скачать руководство пользователя страница 1

-1-

Installation Guide

10/100 Fast Ethernet Managed

Switch with Fiber Connectivity

KS-801

DOC.001002-KS801-K

Содержание KS-801

Страница 1: ... 1 InstallationGuide 10 100 Fast Ethernet Managed Switch with Fiber Connectivity KS 801 DOC 001002 KS801 K ...

Страница 2: ...serves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 ...

Страница 3: ... 3 9 Port Fast Ethernet Managed Switch with Fiber Connectivity DOC 001002 KS801 NK P N 750 0150 002 INSTALLATION GUIDE ...

Страница 4: ...ence Characteristics of Information Technology Equipment This device complies with CISPR Class A WARNING This is a Class A product In a domestic environment this product may cause radio inter ference in which case the user may be required to take adequate measures CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is i...

Страница 5: ... 10 100BASE TX Fast Ethernet Ports 15 3 3 Fast Ethernet Fiber Slot 17 3 4 Making Trunk Connections 20 3 5 Making Sniffer 22 4 LED Indicators 23 4 1 LED Panels 23 4 2 Interpretation 23 5 Performing Network Management 24 5 1 Management Support 24 5 2 Management objects 25 5 3 Setting IP Address 26 5 4 Console Management 26 5 5 Web Management 27 5 6 Telnet Management 27 5 7 SNMP Management 28 5 8 Upg...

Страница 6: ... It also provides one Fast Ethernet Fiber slot for uplink to fiber backbone The key features of the switch units are Easy Migration With 10BASE T 100BASE T support the switch provides a non disruptive and smooth migration path from Ethernet to Fast Ethernet network Easy Installation With the functions of auto speed sensing and auto negotiation on each port the switches support plug and play instal...

Страница 7: ...slot supports 100BASE FX ST fiber module for MM fiber 100BASE FX SC fiber module for MM and SM fiber 100BASE FX MT RJ fiber module for MM and SM fiber 100BASE FX VF 45 fiber module for MM fiber Self learning for network configuration Store and forward switching to ensure only good packets are forwarded Full duplex or half duplex operation support for all switched ports Forwarding and filtering at ...

Страница 8: ...tures Telnet for remote control Provides one RS232 local console port IEEE 802 1d Spanning Tree protocol TFTP software upgrade capability Web based management SNMP management SNMP agent RFC 1155 1157 MIB II private MIB ...

Страница 9: ...tLED Power status TPPortLED Link Activity Speed Duplex Collision status per port Filtering rate 14 880 pps for Ethernet 10BASE T 148 8 Kpps for Fast Ethernet 100BASE TX and FX Forwardingrate 14 880 pps for Ethernet 10BASE T 148 8 Kpps for Fast Ethernet 100BASE TX and FX Filteringaddress Multicast Broadcast Unicast address MAC addresses 4K entries Trunking 2 trunks max 4 trunking ports per trunk ma...

Страница 10: ...ntries around the world Before connecting the supplied power cord into the switch check to see that the cord voltage and current rating conform to the standards of the country of operation 2 1 Packing List The switch has the following components shipped with it One switch unit One AC power cord One RS232 console cable 19 inch rack mount kit CD for installation guide software modules MIB file and s...

Страница 11: ... 100 Port 1 9 10BASE T 100BASE TX Port 1 9 Crossover SW Crossover setting switch for 10 100 Port 9 100 Fiber Slot 100M Fiber slot for Port 9 LEDindicators LED display for power and all port status AC power socket Plug in socket for AC power cord Console port Connector for local console connection ...

Страница 12: ...tion space between the switch and the objects around it Desktop Mounting For mounting the switch into a 19 inch rack a pair of mounting brackets is included in the pack Install Rack Mount Brackets Install the switch into a 19 inch rack as illustrated in the following figure Install the Switch into a 19 inch Rack ...

Страница 13: ...ion types one is 10 100BASE TX RJ 45 connector and the other is 100BASE FX fiber slot The Fast Ethernet fiber slot can accommodate one optional Fast Ethernet fiber module The following table lists the connectors provided on each network ports Port Standard Connector type Mark Port 1 8 10 100BASE TX MDI X RJ 45 1X 8X Port 9 10 100BASE TX RJ 45 9X crossover SW defines RJ 45 type Port 9 100BASE FX 10...

Страница 14: ...ight through UTP cable MDI RJ 45 connector is provided for easy uplink via standard straight through UTP to other device that supports MDI X RJ 45 connector The following table shows the pin assignments of MDI X and MDI RJ 45 connector respectively PIN MDI X Jacks MDI Jack 1 Rx Tx 2 Rx Tx 3 Tx Rx 6 Tx Rx 4 5 7 8 NC NC Crossover SW This push button switch is dedicated for Port 9 RJ 45 jack When pus...

Страница 15: ...o a non auto negotiation device half duplex mode is used However the ports can auto detect the connection speed ManualConfiguration The ports are configured to be enabled for auto negotiation as factory default However it also can be changed and stick to one of the follow ing configurations through network management operation _ 10M Half duplex _ 10M Full duplex _ 100M Half duplex _ 100M Full dupl...

Страница 16: ...ng straight through UTP cable make sure MDI X to MDI connection rule is followed The following figure illustrates the pin assignments of a straight through UTP and a crossover UTP cable Straight through and Crossover UTP Cable It is suggested to use straight through UTP cables for all UTP connec tions The maximum length and UTP cable categories used for the con nections to a 10BASE T device and 10...

Страница 17: ...um length 800 T ST MM 2 Km 800 C SC MM 2 Km 800 SA SC SM 15 Km 800 S3 SC SM 30 Km 800 S5 SC SM 50 Km 800 JM MT RJ MM 2 Km 800 JS MT RJ SM 15 Km 800 VM VF 45 MM 2 Km MM Multimode fiber cable SM Single mode fiber cable Switched port 9 supports two types of connections One type is UTP connection through Port 9X The other is fiber connection through slot FIBER respectively Both types of connections ca...

Страница 18: ... modules Different type of modules is mounted with different fiber connector FiberModule Topview Fiber Jumper Setting The jumper group J1 on the module is used to enable or disable the fiber module The following figure shows the jumper setting defini tions Fiber Jumper Setting ...

Страница 19: ... FX Speed 100Mbps Duplex mode Full duplex or half duplex Wavelength 1300nm Fiber Connectors ST SC MT RJ VF 45 Fiber cable MM 50 125mm 62 5 125mm recommended SM 9 125mm recommended ModuleInstallation 1 Turn off the power to the switch unit 2 Open the cover of Fiber slot 3 Set Fiber jumper J1 4 Insert the module into slot until it is seated properly 5 Screw the module onto the chassis securely ...

Страница 20: ...ts can be configured optionally as trunking ports through the network management operation Two trunking ports composes one trunk Two switch units can be cascaded through one trunk The aggregated bandwidth of one trunk can be up to 400Mbps if 2 trunking ports are used for one trunk The switch supports the following trunk configurations Configuration Trunk Trunking ports 1 None None 2 1 Trunk Port 1...

Страница 21: ...2 One trunking port can only belong to one trunk 3 Only one trunk can exist between two switch units 4 Crossover UTP cables should be used at the same time for one trunk connection The length of each cable can be up to 100 meters 5 When the switched data ports are enabled as trunking ports they can only serve trunking function but no other data function 6 Since the trunking is proprietary the swit...

Страница 22: ... for monitor traffic in switched networks Any switched port can be defined as a sniffer port which can monitor one or more port traffic Normally it is connected to a LAN analyzer equipment When doing sniffer configure MonitoredPorts Configure the ports you want to monitor All monitored port traffic will be copied to the sniffer port Up to 8 monitored ports can be selected in the switch Sniffer Por...

Страница 23: ...l LED indicate the duplex mode used and collision status FX LED indicate the fiber module is installed and active The LED indicators labeled a port number on top are corresponding to a specific 10 100BASE TX port The states and indications are LED STATE INDICATION Power Off Power Off Power On Power On Link Act On Link active Link Act Off No active link Link Act Blink Tx or Rx activities 10 100M On...

Страница 24: ... and can be managed by using the following methods _ Direct console connection over an RS232 cable _ Web browser software from Internet or Intranet over TCP IP network _ Telnet software over TCP IP network _ SNMP manager software over TCP IP network The following figure illustrates a management model diagram ...

Страница 25: ...d bad drop packet counts Administrator _ Basic Management IP address settings SNMP settings _ Advanced Management Spanning tree protocol settings Trunking settings Sniffer settings _ Console Port Information console baud rate data bits parity stop bits flow control _ Port Controls Port enable disable Port speed setting Port duplex setting Port flow control setting _ Security Manager change user na...

Страница 26: ...fore performing any in band management operation When you log on to the switch console port for the first time a sign on string appears and you are prompted for a console login name and pass word The factory default login name is admin and password is 123 If you desire you can change this password after you log on 5 4 Console Management Any PC running Windows 95 98 or NT can be used as a console U...

Страница 27: ...r Microsoft Internet Explorer 4 0 or later on any platform Con nect to the managed unit using the IP address as URL address http xxx xxx xxx xxx Refer to the operation manual provided in the supplied CD ROM for the details 5 6 Telnet Management Use Telnet software to perform the management operation The most convenient solution is using the built in Telnet function in a Windows 95 98 or NT PC Ente...

Страница 28: ...de Firmware The switch supports Software Upgrade feature via two methods 1 Via TFTP protocol TFTP file transfer functions allow you to perform software upgrade over network 2 Via Console port One file transfer utility program SFTP EXE is provided to perform software upgrade via RS232 console port TFTPUpdateFirmware If you select TFTP Update Firmware command from web management screen specify the f...

Страница 29: ...te the utility program SFTP EXE from your DOS window 4 When finishing the file transfer reboot your switch to make the firmware update effect Contact your dealer for any new available software version 5 9 Support This guide covers the basic information about the management func tions supported by the managed switch The detailed operation guides for all management functions are available in the sof...

Отзывы: