Страница 1: ... 1 INDUSTRIAL 1000BASE T TO 1000BASE X MEDIA CONVERTERS KCD 400 Series Installation Guide DOC 100525 KCD 400 ...
Страница 2: ...serves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 ...
Страница 3: ...s device must accept any interference received including the interference that may cause CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is indica tive that this equipment meets or exceeds the following technical stan dards EMC Class B EN55022 2006 A1 2007 Class B EN61000 3 2 2006 Class A EN61000 3 3 2008 EN55024 19...
Страница 4: ... 13 2 1 Unpacking 13 2 2 Safety Cautions 14 2 3 DIN Rail Mounting 15 2 4 Panel Mounting 17 2 5 Applying Power 19 2 6 Power Failure Relay Output 22 2 7 Making Twisted Pair Copper Port Connection 23 2 8 Making Fiber Port Connection 24 3 LED Indicators 25 3 1 LED Indicators 25 Appendix Model Optical Specifications 26 ...
Страница 5: ...ment the converters are designed with the follow ing enhanced features exceeding that of commercial media converters High and wide operating Temperature Wide operating voltage range for DC power input Power input interface Industrial screw terminal block and DC power jack for external commercial power adapter as option DIN rail mounting support for industrial enclosure Screw panel mounting support...
Страница 6: ...tings is required Link Fault Pass Through this function allows link fault status passes through between copper link and fiber link transparently Far End Fault function on fiber port Transparent conversion to any type of packet frame No packet length limitation Diversified mounting support desktop mounting wall mounting optional Din Rail support Low power consumption Two power interface type screw ...
Страница 7: ... 7 1 2 Specifications This figure shows the important components of the converter ...
Страница 8: ...iber transceiver Data Speed 1000Mbps Duplex Mode Full duplex Cable Types MMF 50 125 62 5 125 SMF 9 125 Link Distance MMF up to 500m SMF model dependent Eye Safety compliance IEC825Class1 Refer to Appendix for detailed optical specifications LEDIndicators LED DISPLAY STATE INTERPRETATION PWR Power status ON Power on OFF Power off SFP SFP slot status ON SFP transceiver is installed OFF No SFP transc...
Страница 9: ...ation Conversion Full wire speed 1000Mbps 1 488 00pps at 64 byte packets Packet Types Transparent and no modification for IEEE 802 3 standard packets IEEE 802 1Q VLAN tagged packets Packet Length Nolimit Mechanical Dimension base W28mmxD82mmxH95mm Housing Enclosed metal with no fan Mounting Support DIN rail mounting Panel mounting Weight 252g Environmental Operating Temperature Typical 20o C 70o C...
Страница 10: ... EN55022 2006 A1 2007 EN61000 3 2 2006 EN61000 3 3 2008 EN55024 1998 A1 2001 A2 2003 IEC 61000 4 2 2009 ESD Test IEC 61000 4 3 2006 A1 2008 RS Test IEC 61000 4 4 2004 EFT BURST Test IEC 61000 4 5 2005 Surge Test IEC 61000 4 6 2009 CS Test IEC 61000 4 8 2001 Magnetic Field IEC 61000 4 11 2004 Volatge Int Dips ...
Страница 11: ...atically Link Fault Pass Through Function When a link fault is detected on the copper port the device will force a link down on the fiber port immediately Similarly a link fault detected on the fiber port will also force a link down on the copper port As illustrated in the following figure this function allows to pass copper link fault to the remote link partner and makes the converter like a twis...
Страница 12: ...he remote connected device to indicate a remote fault is detected It also is capable to receive FEFI signal sent from the remote link partner if the link partner detected a receiving fault Upon receiving an FEFI signal it indicates a link failure occurred on the transmitting path This function allows the converter to report a fiber link fault even when a link failure occurred on transmitting fiber...
Страница 13: ...tact your local reseller for replacement The following are available optional accessories Panel Mounting Bracket The bracket is used for mounting the converter on a panel surface Commercial rated AC power adapters RatedAC120V 60HzDC7 5V1A RatedAC230V 50HzDC7 5V1A RatedAC100V 50 60HzDC7 5V1A RatedAC240V 50HzDC7 5V1A The adapters are used for supplying DC power to the converter via DC power jack int...
Страница 14: ... replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects into the openings of your system Doing so can cause fire or electric...
Страница 15: ...N rail are 1 Install the mounting bracket onto the device unit as shown below 2 Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can clamp on the upper edge of the DIN rail 3 Clamp the unit to the DIN rail and make sure it is mounted securely 4 Make sure that there are proper heat dissipation from and adequate ventilation around the device ...
Страница 16: ... 16 The final mechanical dimensions after installingDINrail mounting bracket are ...
Страница 17: ...device on a plane surface securely The mounting steps are 1 Install the mounting bracket on the device unit 2 Screw the bracket on the device unit 3 Screw the device unit on a panel 4 Make sure that there are proper heat dissipation from and adequate ventilation around the device Do not place heavy objects on the device ...
Страница 18: ... 18 The screw locations and final dimension are shown below ...
Страница 19: ...gTerminal Blocks Either DC1 interface or DC2 interface can be used to receive DC power from an external power system Or DC2 also can be used to deliver the power received on DC1 to next device in cascading way DC1 Vdc Positive terminal DC1 Vdc Negative terminal DC2 Vdc Positive terminal DC2 Vdc Negative terminal Three 2Pterminal plugs are provided together with the device Two of the three plugs ar...
Страница 20: ...perly Screw the wire with plug securely Then plug in DC1 contacts If cascading the power to next device is needed install the power wires and plug for another switch Then use DC2 contacts Note Only up to four device units can be cascaded to receive power from one main power input source ...
Страница 21: ...0HzDC7 5V1A RatedAC240V 50HzDC7 5V1A Connect power adapter DC plug to the DC power jack of the converter before connecting to the AC outlet Connect the power adapter to the AC outlet Note Before you begin the installation check the AC voltage of your area The AC power adapter which is used to supply the DC power for the unit should have the AC voltage matching the commercial power voltage in your ...
Страница 22: ...s labeled PF and PF in the terminal block interface Use the provided 2P terminal plug for signal wiring and plug into the PF contacts The function is designed as Power is normal PF contact is shorted with PF contact Power failure PF contact is disconnected with PF contact Note Be sure the voltage applied on PF contacts is within the specification of 30VDC 1A max or 120VAC 0 5A max ...
Страница 23: ...ASE T 4 pair UTP Cat 5e or 6 EIA TIA 568B 100 ohm STP Link distance Up to 100 meters Note The copper port is featured with auto MDI MDI X crossover de tection and configuration function No matter a straight through cable or crossover cable is connected the copper port can sense the receiving pair automatically and configure itself to match the connection ...
Страница 24: ... is seated securely in the slot place the bail in lock position Connecting Fiber Cables LC connectors are commonly equipped on most SFP transceiver mod ules Identify TX and RX connector before making cable connection The following figure illustrates a connection example between two fiber ports Make sure the RX to TX connection rule is followed on the both ends of the fiber cable Note For Bi Di Bid...
Страница 25: ...PWR Power status ON The device is powered on OFF The device is powered off SFP SFP slot status ON An SFP transceiver is installed OFF No SFP transceiver is installed LINK Link status ON Copper fiber link up OFF Copper fiber link down BLINK Copper fiber link with data traffic OL Optical status ON Fiber port optical signal detected OFF Fiber port no optical signal ...
Страница 26: ...velength Fiber Distance Temperature SX LC 850nm 50 125MMF500m 20 70o C 62 5 125MMF200m LX LC 1310nm MMF550m 20 70o C SMF10km LX20 LC 1310nm SMF20km 20 70o C LX110 LC 1550nm SMF110km 20 70o C Optical Specifications KCD 400 xxx FX TxPower Sensitivity Max RxPower SX LC 9 5 4dBm 18dBm 0dBm LX LC 9 5 3dBm 20dBm 3dBm LX20 LC 8 2dBm 23dBm 1dBm LX110 LC 0 5dBm 30dBm 8dBm ...