2.3 Applying Power

Before you begin the installation, check the AC voltage of your area. The
AC power adapter which is used to supply the DC power for the unit should
have the AC voltage matching the commercial power voltage in your area.

The AC Power Adapter Specifications

AC input power:

AC power voltage of your area, options -
Rated AC120V/60Hz DC7.5V 1A
Rated AC230V/50Hz DC7.5V 1A
Rated AC100V/50-60Hz DC7.5V 1A
Rated AC100V/50-60Hz DC5V 1A
Rated AC240V/50Hz DC7.5V 1A

Steps to apply the power to the converters are:

1. Connect power adapter DC plug to the DC input jack located on the

back of the converter before connecting to the AC outlet.

2. To ensure against accidental disconnection, tie the DC cable with

the cable tie located the back of the converter.

3. Connect the power adapter to the AC outlet.

4. Check Power LED indication.

Содержание KC-300D Series

Страница 1: ... 1 10 100BASE TX TO 100BASE FX MEDIA CONVERTERS KC 300D Series Installation Guide DOC 060215 KC 300D ...

Страница 2: ...serves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 ...

Страница 3: ...e may not cause harmful interference and 2 this device must accept any interference received including the interference that may cause CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is indica tive that this equipment meets or exceeds the following technical stan dards EMC Class B EN 50081 1 1992 EN55022 EN61000 3 2...

Страница 4: ...cking 13 2 2 Mounting the Device 13 2 3 Applying Power 14 2 4 Making TP Port Connection 15 2 5 Making FX Port Connection 16 2 6 LED Indicators 18 3 Optional Configuration Settings 19 3 1 User Inaccessible Jumpers 19 3 1 1 Forwarding Mode Setting JP1 20 3 1 2 802 3x Function Setting JP2 21 3 1 3 FX Duplex Setting JP3 21 3 2 JP1 JP3 Factory Default Settings 21 ...

Страница 5: ... speed and media type Support full wire speed conversion Support 10Mbps and 100Mbps speed on TP connections Auto MDI MDI X detection function on the TP port Auto negotiation function on the TP port Link fault pass through function Provide manual configuration settings for TP port to support connection to non auto negotiation devices Transparent to 802 1Q VLAN tagged packets Far End Fault function ...

Страница 6: ...etection Signal Compliance IEEE802 310BASE T 802 3u100BASE TX Data Speed 10Mbps or 100Mbps Duplex Mode Half duplex or Full duplex Configuration Auto negotiation capable and optional forced manual settings Cable Types 10Mbps Category 3 4 or 5 UTP 100Mbps Category 5 UTP Supported Link Distance Up to 100 meters ...

Страница 7: ...UserAccessibleSettings SW NO SETTING STATE FUNCTION SW1 TPPortConfiguration OFF Auto negotiation default ON Forcedmode SW2 TPPortDuplex OFF Fullduplex default ON Halfduplex SW3 TPPortSpeed OFF 100Mbps default ON 10Mbps SW4 Link Fault Pass Through OFF Disable default ON Enable SW5 Reserved OptionalSettings UserinaccessibleJP1 JP3onboard NO SETTING STATE FUNCTION JP1 Forwarding mode Open Store and f...

Страница 8: ...ink up and no traffic OFF Link fault Blink Rx Tx activities FXOL FX port optical link ON Optical signal is detected OFF No optical signal DCPowerInput DC Input Jack D6 3mm D2 0mm Operating Input Voltages 4 75V 12 6V Power consumption 2Wmax 0 27A 7 5V Power Supply Options External AC DC power adapters RatedAC120V 60HzDC7 5V1A RatedAC230V 50HzDC7 5V1A RatedAC100V 50 60HzDC7 5V1A RatedAC100V 50 60HzD...

Страница 9: ... and forwardmode No limit at smart forward mode 100to100 Flow Control Back pressure for half duplex mode 802 3xpause framebaseforfullduplexmode Mechanical Dimension H23mmxW72 5mmxD108mm Housing Enclosed metal with no fan Mounting Desktop Wall mount Center chassis Weight 210g Environmental Operating Temperature 20o C 60o C KC 300D EC 5o C 50o C Other models Storage Temperature 20o C 85o C Relative ...

Страница 10: ...4 SC SMF 1310nm 5 0dBm 34dBm 300D SL6 SC SMF 1310nm 5 0dBm 35dBm 300D SL7 SC SMF 1310nm 3 3dBm 37dBm 300D SL9 SC SMF 1310nm 0 5dBm 37dBm 300D SL10 SC SMF 1550nm 3 3dBm 37dBm 300D SL12 SC SMF 1550nm 0 5dBm 37dBm Single Fiber Bi Di WDM Series Model Port Fiber Wavelength TxPower Rx Sensitivity 300D W3515 SC SMF Tx1310nm 14 8dBm 31dBm Rx1550nm 300D W5315 SC SMF Tx1550nm 14 8dBm 31dBm Rx1310nm 300D W35...

Страница 11: ...e automatically when each time a link is being established FarEndFaultFunction The FX port is facilitated with this function which conforms to IEEE 802 3u 100BASE FX specifications When the FX port detects a link failure on its receiving circuitry it will send out an FEFI Far End Fault Indication signal to the remote connected device to indicate a remote fault is detected It also is capable to rec...

Страница 12: ...e TP port will force a link down on the FX port Similarly a link fault detected on the FX port will also force a link down on the TP port As illustrated in the following figure this function allows to pass TP link fault to the remote link partner and makes the converter like a TP cable extender ...

Страница 13: ...from and adequate ventilation around the device Do not place heavy objects on the device WallMounting The media converter also can be mounted on a wall On bottom of the device wall mounting hole is provided for wall mounting Installation into Center Chassis KC 1300 The media converter also can be installed in KC 1300 center chassis The center chassis provides the power supply to the converter Up t...

Страница 14: ... your area options RatedAC120V 60HzDC7 5V1A RatedAC230V 50HzDC7 5V1A RatedAC100V 50 60HzDC7 5V1A RatedAC100V 50 60HzDC5V1A RatedAC240V 50HzDC7 5V1A Steps to apply the power to the converters are 1 Connect power adapter DC plug to the DC input jack located on the back of the converter before connecting to the AC outlet 2 To ensure against accidental disconnection tie the DC cable with the cable tie...

Страница 15: ... TIA 568 100 ohm STP Link distance Up to 100 meters ConfigurationSetup To make a proper connection the following configuration settings are recommended TP port link partner SW1 SW2 SW3 Auto negotiation device Off auto Off full duplex Off 100M Fixed 10M half duplex device On forced On half duplex On 10M Fixed 100M half duplex device On forced On half duplex Off 100M Fixed 10M full duplex device On ...

Страница 16: ... MMF 2km 300D SA2 SC 1310nm DuplexSMF 20km 300D SL2 SC 1310nm DuplexSMF 20km 300D SL3 SC 1310nm DuplexSMF 30km 300D SL4 SC 1310nm DuplexSMF 40km 300D SL6 SC 1310nm DuplexSMF 60km 300D SL7 SC 1310nm DuplexSMF 70km 300D SL9 SC 1310nm DuplexSMF 90km 300D SL10 SC 1550nm DuplexSMF 100km 300D SL12 SC 1550nm DuplexSMF 120km Duplex FiberCWDM Series Model Connector Wavelength Fiber Ref Distance 300D CxxW40...

Страница 17: ...F 15 20km Rx 1310nm 300D W3540 Bi Di SC Tx 1310nm Single SMF 40km Rx 1550nm 300D W5340 Bi Di SC Tx 1550nm Single SMF 40km Rx 1310nm Since the WDM single fiber media converters use different wavelengths for transmission and receiving respectively the link partner device lo cated on the remote end of the single fiber should match the wavelength used on the single fiber converter ...

Страница 18: ... Full duplex Off Half duplex Blink Collisions on half duplex FXLINK FX port link status On Link up and no traffic Off Link fault Blink Rx Tx activities FXOL FX port optical link On Optical signal is detected Off No optical signal is detected Link Fault Pass Through Function is enabled TPLINK FXLINK FXOL Interpretation On On On Both TP and FX ports link up Off Off On 1 TP port link fault or 2 FX po...

Страница 19: ...rs The setting jumpers are not accessible by users generally For accessing these jumpers the upper case must be removed from the product Re moving the case must be performed by an authorized and experienced technical person The setting jumper block is located on the position shown below The setting functions are as follows JP1 Forwarding mode setting Open Store and forward mode Short Smart forward...

Страница 20: ...speed on both TP port and FX port Direct conversion method converts the signal between TP port and FX port without storing the received packet on one port then forwarding to another port The media converter operates with the minimum latency Note 1 In direct conversion be sure both devices connected to the TP port and FX port have same duplex mode for proper transmission 2 In direct conversion 802 ...

Страница 21: ...s method uses pause frames for one port to stop further transmission from its link partner 3 1 3 FX Duplex Setting JP3 This setting is used to set the duplex mode of the FX port 3 2 JP1 JP3 Factory Default Settings The factory default settings for JP1 JP2 and JP3 are as follows JP1 Open Store and forward mode JP2 Open 802 3x function is enabled JP3 Open FX port full duplex ...

Отзывы: