4
EN
OUTPUT MANAGEMENT THROUGH OPERA REMOTE COMMANDS (STAND-ALONE)
OUTPUT MANAGEMENT THROUGH PANEL SCENARIOS
What follows is valid only for using
auxi wls
as stand-alone device. To manage outputs with
opera
remote command it is necessary to enroll
it. As explained in ‘Programmation’ paragraph, each key of remote command can be associated with an
auxi wls
or - - keys can be
programmed to manage the relay outputs of 3 different
auxi wls
. To associate a single key of remote command to an
auxi wls
allows to manage
up to 3
auxi wls
at the same time, with the same remote command, if these are covered by the RF channel. In case all the keys of
opera
remote
command are associated to the same
auxi wls
, these operate as follows:
In case
auxi wls
is associated to a
lares
control panel, the activation / de-activation of the outputs can be managed also through the panel. In
the same way as the panel outputs, the outputs on
auxi wls
can commute when a particular event occurs, or can be manually activated through
web server.
In case the keys of the same
opera
remote command are associated to different
auxi wls
, by pressing a key the relay outputs react as follows:
Key
This key turns the 2 outputs in stay mode. This action is confirmed by turning on
the central LED on
opera
remote command
Key
This key manages the first relay output. By pressing this key, the outputs react
depending on the programmation.
• If the output is programmed as
monostable
it be activated and remains
active during the ON time. In case the output is already active and
programmed as indipendent or SPTD (
change over switch
), the ON time is
re-started. Otherwise it turns off, if the output is programmed as interlocked.
• If the output is programmed as
bistable
, it commutates at every pression
of the key
To confirm the operation,
opera
remote command turns ON its left LED, if the
outputs is activated and turns ON the central LED, if the output is deactivated.
Key
This key manage the second relay output By pressing this key, the outputs
react depending on the programmation.
• If the output is programmed as
monostable
it be activated and remains
active during the ON time. In case the output is already active and
programmed as indipendent or SPTD (
change over switch
), the ON time is
re-started. Otherwise it turns off, if the output is programmed as interlocked.
• If the output is programmed as
bistable
, it commutates at every pression
of the key
To confirm the operation,
opera
remote command turns ON its left LED, if the
outputs is activated and turns ON the central LED, if the output is deactivated
Key
This key allows to visualize the outputs status. The short pression on this key
displays the status of the first output. If the output is active, the left LED of
opera turns ON, otherwise it turns ON the central one. The long pression on
the same key displays the status of the second output in the same way as
the first one.
Key
Key
Key
In case the outputs are programmed as indipendents, a short pression of
the key manages the first output and a long pression manages the second
output. In case the output are programmed as SPTD (change over switch),
there is no difference between the short or the long pression of the key,
considering that the outputs commute together.
In case the outputs are programmed as interlocked, the outputs reaction
depends on the previous status of the relay outputs. The activation sequency
is: first output activation, output de-activation, second output activation,
output de-activation, first output activation again and so on. The LED on
opera remote command, corresponding to the pressed key, turns ON to
confirm the operation (
left led > key , right led > key
).
Key
Not used
key
key
monostable output
indipendent / SPTD
key
monostable output
interlocked
key
bistable output
key
key
short pression
key
long pression
ON time
ON time
ON time
the same as key 1 but on output 2
OUTPUT 1
OUTPUT 1
OUTPUT 2
OUTPUT 1
OUTPUT 1
OUTPUT 1
OUTPUT 1
OUTPUT 1
key
short pression
indipendent / SPTD
key / /
long pression
indipendent / SPTD
key / /
short pression
interlocked
key / /
long pression
interlocked
not used
output 1
on auxi wls 0 / 1 / 2
output 1
on auxi wls 0 / 1 / 2
output 2
on auxi wls 0 / 1 / 2
output 2
on auxi wls 0 / 1 / 2