5 Installation at Site
30 of 80
Vitacast / Vitacast Bloc
WARNING
The volute casing and casing/discharge cover take on the same temperature as the
fluid handled
Risk of burns!
▷
Insulate the volute casing.
▷
Fit protective equipment.
CAUTION
Heat build-up in the bearing bracket
Damage to the bearing!
▷
Never insulate the bearing bracket, bearing bracket lantern and casing cover.
5.5 Checking the coupling alignment
DANGER
Inadmissible temperatures at the coupling or bearings due to misalignment of the
coupling
Explosion hazard!
Risk of burns!
▷
Make sure that the coupling is correctly aligned at all times.
CAUTION
Misalignment of pump and motor shafts
Damage to pump, motor and coupling!
▷
Always check the coupling after the pump has been installed and connected to
the piping.
▷
Also check the coupling of pump sets supplied with pump and motor mounted
on the same baseplate.
B
A
A
B
a)
b)
B
B
A
A
1
1
2
2
1
1
Fig. 6:
Checking the coupling alignment: Coupling without spacer sleeve (a) or Coupling with spacer sleeve (b)
1
Straight-edge
2
Gauge
ü
The coupling guard and its footboard, if any, have been removed.
1. Loosen the support foot and re-tighten it without transmitting any stresses and
strains.
2. Place the straight-edge axially on both coupling halves.