4 Description of the Pump (Set)
18 of 80
Vitacast / Vitacast Bloc
Position
Code
Description
32
2)
Standard
X
Non-standard (BT3D, BT3), including ATEX
33
Draining facility
D
Casing drain with plug
O
No drain
P
Casing drain via piping
V
Casing drain via valve
34
Generation
A
Vitacast
4.3 Designation
Table 8:
Designation example
Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
V A B
0 3 2 - 0
2
5
-
1
4
5
0
4
0
2
K
B
T
8
1
M
E
C
C
S
X
O
A
See name plate and data sheet
See data sheet
Table 9:
Designation key
Position
Code
Description
1-4
Pump type
VAB
Vitacast Bloc
VABI
Vitacast Bloc Inducer
5-16
Size, e.g.
040
Nominal suction nozzle diameter [mm]
025
Nominal discharge nozzle diameter [mm]
200
Nominal impeller diameter [mm]
17-19
Motor rating P
N
[kW]
007
0,7
...
...
550
55,00
20
Number of motor poles
21
Scope of supply
K
Ball feet
L
Bearing bracket
M
Motor foot
T
Round base feet
V
Trolley
22-23
Shaft seal type
B
Single mechanical seal, internal, dead-end arrangement, without
flushing
BQ
Single mechanical seal, internal, dead-end arrangement, external
flushing (quench)
DB
Double mechanical seal, external, in back-to-back arrangement
I
Single mechanical seal, internal, dead-end arrangement, internal
circulation
J
Single mechanical seal, external, without flushing
24-26
Seal code, single mechanical seal, internal
T00
GCEGG
2)
Blank