7
Servicing/Maintenance
7.1
Safety regulations
CAUTION
Improperly serviced pump set
Damage to the pump set!
▷
Service the pump set regularly.
▷
Prepare a maintenance schedule with special emphasis on lubricants, shaft seal
and coupling.
The operator ensures that all maintenance, inspection and installation work is
performed by authorised, qualified specialist personnel who are thoroughly familiar
with the manual.
WARNING
Pump set started up inadvertently
Risk of injury by moving parts!
▷
Make sure that the pump set cannot be started up accidentally.
▷
Always make sure the electrical connections are disconnected before carrying
out work on the pump set.
WARNING
Fluids posing a health hazard or hot fluids
Risk of personal injury!
▷
Observe all relevant laws.
▷
When draining the fluid take appropriate measures to protect persons and the
environment.
▷
Decontaminate pumps handling fluids posing a health hazard.
A regular maintenance schedule will help avoid expensive repairs and contribute to
trouble-free, reliable operation of the pump (set) with a minimum of maintenance
expenditure and work.
NOTE
All maintenance, service and installation work can be carried out by KSB Service. Find
your contact in the attached "Addresses" booklet or on the Internet at
".
Never use force when dismantling and reassembling a pump set.
7.2
Servicing/inspection
7.2.1 Supervision of operation
DANGER
Incorrectly serviced shaft seal
Fire hazard!
Leakage of hot fluids!
Damage to the pump set!
▷
Regularly service the shaft seal.
7 Servicing/Maintenance
22 of 36
Trialine / Trialine Z
Содержание Trialine
Страница 1: ...In line Pump In line Twin Pump Trialine Trialine Z Installation Operating Manual ...