8 Trouble-shooting
77 of 96
Magnochem-Bloc
8 Trouble-shooting
WARNING
Improper work to remedy faults
Risk of injury!
▷
For any work performed to remedy faults, observe the relevant information
given in this operating manual and/or in the product literature provided by the
accessories manufacturer.
If problems occur that are not described in the following table, consultation with the
KSB customer service is required.
A
Pump delivers insufficient flow rate
B
Motor is overloaded
C
Excessive discharge pressure
D
Leakage at the pump
E
Vibrations during pump operation
F
Impermissible temperature increase in the pump
Table 21:
Trouble-shooting
A B C D E
F Possible causes
Remedy
10)
✘
-
-
-
-
- Pump delivers against an excessively high
pressure.
Re-adjust to duty point.
Check system for impurities.
Fit a larger impeller.
11)
Increase the speed (turbine, I.C. engine).
✘
-
-
-
✘ ✘
Pump or piping are not completely vented
and/or primed.
Vent and/or prime.
✘ ✘
-
-
✘
- Supply line or impeller clogged
Remove deposits in the pump and/or piping.
✘
-
-
-
-
- Formation of air pockets in the piping
Alter piping layout.
Fit a vent valve.
✘
-
-
-
✘ ✘
NPSH
available
(positive suction head) is too low.
Check/alter fluid level.
Fully open the shut-off element in the suction
line.
Change suction line, if the friction losses in the
suction line are too high.
Check any strainers installed/suction opening.
Observe permissible speed of pressure fall.
✘
-
-
-
-
- Increased axial thrust
11)
Correct rotor adjustment.
✘
-
-
-
-
- Wrong direction of rotation
Check the electrical connection of the motor
and the control system, if any.
✘
-
-
-
-
- Speed is too low.
11)
▪
Operation with frequency inverter
▪
Operation without frequency inverter
▪
Increase voltage/frequency at the
frequency inverter in the permissible
range.
▪
Check voltage.
✘
-
-
-
✘
- Suction lift is too high.
Clean suction strainer and suction lines.
Correct/alter fluid level.
Change suction line.
-
✘
-
-
✘
- Pump back pressure is lower than specified in
the purchase order.
Adjust duty point accurately by means of the
shut-off element.
In the case of persistent overloading, turn
down impeller.
11)
-
✘
-
-
-
- Density or viscosity of fluid handled higher
than stated in purchase order
11)
10)
Release pump pressure before attempting to remedy faults on parts which are subjected to pressure.
11)
Consult the manufacturer.