7 Servicing/Maintenance
41 of 64
KWP-Bloc
7.2.3.1.1 Intervals
▪
Under suitable operating conditions the grease-lubricated bearings will run for
15,000 operating hours.
▪
Under unfavourable operating conditions (e.g. high room temperature, high
atmospheric humidity, dust-laden air, aggressive industrial atmosphere) check
the bearings earlier and replace them, if required.
▪
Replace the rolling element bearings after 15,000 operating hours or 2 years of
continuous operation.
7.2.3.2 Oil reservoir (if applicable)
7.2.3.2.1 Intervals
Change to oil every 4000 operating hours but at least once a year.
7.2.3.2.2 Oil quality
Table 16:
Oil quality
Type
Specification
Motor oil
SAE 10 W/20 W
Lubricating oil
CL 32...68 DN 51 517
7.2.3.2.3 Oil quantity
Table 17:
Oil quantity for oil reservoir
Size
Oil quantity
[l]
Horizontal
Vertical
125-100-0250
Approx. 0.3
Approx. 1
080-040-0315
Approx. 0.3
Approx. 1
080-065-0315
Approx. 0.3
Approx. 1
065-040-0250
Approx. 0.5
Approx. 1
100-080-0250
Approx. 0.5
Approx. 1
100-080-0315
Approx. 0.5
Approx. 1
125-100-0315
Approx. 0.5
Approx. 1
7.2.3.2.4 Changing the oil
WARNING
Lubricants posing a health hazard and/or hot lubricants
Hazard to persons and the environment!
▷
When draining the lubricant take appropriate measures to protect persons and
the environment.
▷
Wear safety clothing and a protective mask if required.
▷
Collect and dispose of any lubricants.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.