5 Installation/Commissioning
16 of 40
KSB Guard
5.1.1.2 Installing the gateway antennas
1
2
Fig. 7:
Installing antennas
1
Rod antenna
2
Magnetic base antenna
The antenna cable should not exceed 20 m in length.
1. Screw the supplied rod antenna onto the left connection (Antenna sensor
network).
2. Screw the magnetic base antenna onto the right connection (Antenna LTE).
3. Place the magnetic base antenna in a location that has sufficiently high mobile
5.1.1.3 Electrically connecting the gateway
Connecting to a shockproof socket
1. Plug the mains power cable supplied into the socket.
2. Check the status LED.
Make sure that at least 2 LEDs are lit. This indicates that the connection to the
mobile network is sufficiently strong.
ð
When the mains power cable is connected, the gateway starts automatically and
can then be used.
Alternative connection to customer’s own power supply
DANGER
Improper work on electrical connection
Electric shock!
▷
The gateway may only be opened by a qualified electrical technician.
▷
Electrical work may only be carried out by a qualified electrical technician.
Alternatively, the mains power cable supplied can also be replaced with the
customer’s own mains power cable:
Содержание Guard
Страница 1: ...KSB Guard Installation Operating Manual ...
Страница 4: ...Contents 4 of 40 KSB Guard 11 EU Declaration of Conformity 35 Index 36 ...
Страница 26: ...6 Operation 26 of 40 KSB Guard The device then automatically switches to stand by mode and all LEDs extinguish ...
Страница 38: ......
Страница 39: ......
Страница 40: ...KSB SE Co KGaA Johann Klein Straße 9 67227 Frankenthal Germany Tel 49 6233 86 0 www ksb com 4079 8 01 EN ...