7.2.3.2.3 Grease quantity
Table 18: Grease quantity for grease-lubricated radial ball bearings to DIN 625
Shaft unit
9)
Code
Grease quantity per
bearing
[g]
25
6305 Z C3
5
35
6307 Z C3
10
55
6311 Z C3
15
7.2.3.2.4 Changing the grease
CAUTION
Mixing greases of differing soap bases
Changed lubricating qualities!
▷
Thoroughly clean the bearings.
▷
Adjust the re-lubrication intervals to the grease used.
1. Only half-fill the bearing cavities with grease.
7.3
Drainage/disposal
WARNING
Fluids posing a health hazard
Hazardous to persons and the environment!
▷
Collect and properly dispose of flushing liquid and any fluid residues.
▷
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
1. For draining the fluid handled use connection 6B (see drawing of auxiliary
connections).
2. If noxious, explosive, hot or other hazardous fluids have been handled, flush the
pump.
Always flush and clean the pump before transporting it to the workshop. Provide
a cleaning record for the pump.
7.4
Dismantling the pump set
7.4.1 General notes/Safety regulations
WARNING
Unqualified personnel performing work on the pump (set)
Risk of personal injury!
▷
Always have repair and maintenance work performed by specially trained,
qualified personnel.
WARNING
Hot surface
Risk of personal injury!
▷
Allow the pump set to cool down to ambient temperature.
Observe the general safety instructions and information. (
9)
Refer to the data sheet for the shaft type.
7 Servicing/Maintenance
42 of 66
Etanorm