![KSB Etachrom NC Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/ksb/etachrom-nc/etachrom-nc_installation-and-operating-manual_2006606038.webp)
7.2 Maintenance/inspection
7.2.1 Supervision of operation
DANGER
Risk of potentially explosive atmosphere inside the pump
Explosion hazard!
▷
The pump internals in contact with the fluid to be handled, including the seal
chamber and auxiliary systems must be filled with the fluid to be handled at all
times.
▷
Provide sufficient inlet pressure.
▷
Provide an appropriate monitoring system.
DANGER
Incorrectly serviced shaft seal
Explosion hazard!
Leakage of hot, toxic fluids!
Damage to the pump set!
Risk of burns!
Fire hazard!
▷
Regularly service the shaft seal.
DANGER
Excessive temperatures as a result of bearings running hot or defective bearing seals
Explosion hazard!
Fire hazard!
Damage to the pump set!
▷
Regularly check the rolling element bearings for running noises.
DANGER
Incorrectly serviced barrier fluid system
Explosion hazard!
Fire hazard!
Damage to the pump set!
Hot and/or toxic fluids could escape!
▷
Service the barrier fluid system regularly.
▷
Monitor the barrier fluid pressure.
CAUTION
Increased wear due to dry running
Damage to the pump set!
▷
Never operate the pump set without liquid fill.
▷
Never close the shut-off element in the suction line and/or supply line during
pump operation.
CAUTION
Impermissibly high temperature of fluid handled
Damage to the pump!
▷
Prolonged operation against a closed shut-off element is not permitted
(heating up of the fluid).
▷
Observe the temperature limits in the data sheet and in the section on
operating limits.
7 Servicing/Maintenance