7.2.1.5.4 Topping up the lubricant
WARNING
Lubricants posing a health hazard
Hazard to persons and the environment!
▷
When filling in the lubricant take appropriate measures to protect persons and
the environment.
CAUTION
Lubricant level too high
Mechanical seal operation is impaired!
▷
Always place the submersible mixer in horizontal position (as shown) for filling
in the lubricant.
903.01
411.01
Fig. 9: Topping up the lubricant
✓
The submersible mixer has been positioned as shown.
✓
The screw plug 903.01 and joint ring 411.01 have been removed.
1. Fill the lubricant through the lubricant filler opening until the lubricant reservoir
overflows.
2. Close screw plug 903.01 again, fitting a new joint ring 411.01.
7.3
Drainage/disposal
WARNING
Fluids posing a health hazard
Hazard to persons and the environment!
▷
Submersible mixers used in fluids posing a health hazard must be
decontaminated.
▷
Collect and properly dispose of flushing liquid and any liquid residues.
▷
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of harmful substances.
1. Always flush the submersible mixer if it has been used for handling noxious,
explosive, hot or other hazardous fluids.
2. Always flush and clean the submersible mixer before sending it to the workshop.
Make sure to add a certificate of decontamination. (
7 Servicing/Maintenance
32 of 52
Amamix® direkt
Goodnal STP ST041 Biological Treatment (KSB Amamix Direct Installation and Operation Manual) Vendor Manual
Q-Pulse Id VM385
Active 29/10/2013
Page 32 of 52