7 Servicing/Maintenance
58 of 126
Amacan S
1589.837/01-EN
7.4.1.3 Lubricant quantity
Table 18:
Lubricant quantity [l] depending on size
Size
Lubricant quantity
[l]
800/850 - 535
2,8
850 - 550
2,8
900/1000 - 600
3,1
900/1000 - 615
3,1
900/1000 - 620
3,1
1000 - 655
4,6
1300 - 820
3,1
7.4.1.4 Changing the lubricant
WARNING
Lubricants posing a health hazard and/or hot lubricants
Hazard to persons and the environment!
▷
When draining the lubricant take appropriate measures to protect persons and
the environment.
▷
Wear safety clothing and a protective mask if required.
▷
Collect and dispose of any lubricants.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
WARNING
Excess pressure inside the pump set
Risk of injury when opening the pump set!
▷
Take care when opening the inner chambers. Equalise the pressure.
WARNING
Improper handling when placing the pump set in a vertical/horizontal position
Personal injury and damage to property!
▷
Select suitable lifting equipment for the size of the pump.
▷
Use appropriate means to secure the pump set against tilting, tipping over or
rolling off.
▷
Maintain a safe distance during lifting operations (load may swing when being
lifted).
▷
Use additional supports for the transport holder to secure it against tilting.
7.4.1.4.1 Draining the lubricant
WARNING
Incorrect positioning/placing down
Personal injury and damage to property!
▷
Position the pump set vertically with the motor on top.
▷
Use appropriate means to secure the pump set against tilting and tipping over.
▷
Refer to the weights given in the data sheet/on the name plate.