5 Installation at Site
42 of 126
Amacan S
1589.837/01-EN
5.4.2 Electrical connection
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe the IEC 61557 regulations as well as any regional regulations.
WARNING
Incorrect connection to the mains
Damage to the power supply network, short circuit!
▷
Observe the technical specifications of the local energy supply companies.
CAUTION
Improper routing of electric cables
Damage to the electric cables!
▷
Never move the electric cables at temperatures below -25 °C.
▷
Never kink or crush the electric cables.
▷
Never lift the pump set by the electric cables.
▷
Adjust the length of the electric cables to the site requirements.
CAUTION
Motor overload
Damage to the motor!
▷
Protect the motor by a thermal time-lag overload protection device in
accordance with IEC 60947 and local regulations.
For the electrical connection observe the circuit diagrams (
in the Annex and the information for planning the control system
(
The pump set is supplied complete with power cables. Always use all cables provided
and connect all marked cores of the control cable.
DANGER
Operating an incompletely connected pump set
Damage to the pump set!
▷
Never start up a pump set with incompletely connected cables or non-
operational monitoring devices.
DANGER
Using damaged power cables
Danger of death from electric shock!
▷
Never connect any damaged power cables.
▷
Visually inspect the power cable before connecting it.
▷
Replace the power cable if it is damaged.