17
Power factor at design point
18
Rated frequency
19
Service factor
20
Starting current
4.4 Design details
Design
▪
Fully floodable submersible pump in discharge tube (submersible motor pump)
▪
Not self-priming
▪
Impeller type
▪
Shaft seal
▪
Two bi-directional mechanical seals in tandem arrangement, with liquid reservoir
▪
Leakage chamber
Bearings
▪
Grease-packed rolling element bearings
Drive
▪
Three-phase asynchronous squirrel-cage motor
4.5 Type of installation
Pump installation is horizontal.
Fig. 5: Type of installation
4 Description of the Pump (Set)
16 of 68
Amacan P