2 Safety
9 of 126
Amacan K
1579.807/07-EN
2 Safety
!
DANGER
All the information contained in this section refers to hazardous situations.
In addition to the present general safety information the action-related safety
information given in the other sections must be observed.
2.1 General
▪
This operating manual contains general installation, operating and maintenance
instructions that must be observed to ensure safe operation of the system and
prevent personal injury and damage to property.
▪
Comply with all the safety instructions given in the individual sections of this
operating manual.
▪
The operating manual must be read and understood by the responsible specialist
personnel/operators prior to installation and commissioning.
▪
The contents of this operating manual must be available to the specialist
personnel at the site at all times.
▪
Information and markings attached directly to the product must always be
complied with and kept in a perfectly legible condition at all times. This applies
to, for example:
– Arrow indicating the direction of rotation
– Markings for connections
– Name plate
▪
The operator is responsible for ensuring compliance with all local regulations not
taken into account.
2.2 Intended use
▪
The pump (set) must only be operated in the fields of application and within the
use limits specified in the other applicable documents.
▪
Only operate pumps/pump sets which are in perfect technical condition.
▪
Do not operate the pump (set) in partially assembled condition.
▪
Only use the pump to handle the fluids described in the data sheet or product
literature of the pump model or variant.
▪
Never operate the pump without the fluid to be handled.
▪
Observe the limits for continuous duty specified in the data sheet or product
literature (Q
min
and Q
max
) (to prevent damage such as shaft fracture, bearing
failure, mechanical seal damage, etc).
▪
Observe the minimum flow rate and maximum flow rate indicated in the data
sheet or product literature (to prevent overheating, mechanical seal damage,
cavitation damage, bearing damage, etc).
▪
Always operate the pump (set) in the direction of rotation it is intended for.
2.2.1 Prevention of foreseeable misuse
▪
Observe the minimum flow velocities required to fully open the swing check
valves to prevent the reduction of pressure and risk of clogging.
(Contact the manufacturer for the required minimum flow velocities/loss
coefficients.)
▪
Never exceed the permissible application and operating limits specified in the
data sheet or product literature regarding pressure, temperature, etc.
▪
Observe all safety information and instructions in this manual.
2.3 Personnel qualification and training
All personnel involved must be fully qualified to transport, install, operate, maintain
and inspect the machinery this manual refers to.