6 Commissioning/Start-up/Shutdown
49 of 126
Amacan K
1579.807/07-EN
6.3 Shutdown/storage/preservation
6.3.1 Shutdown
CAUTION
Uncontrolled backflow of the fluid from the riser
Damage to the pump set!
▷
Prevent any
uncontrolled
backflow of the fluid handled with suitable means.
▷
Control
the fluid backflow, e.g. by throttling the gate valve in the discharge
line.
6.3.2 Measures to be taken for shutdown
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe the EN 61557 regulations as well as any regional regulations.
WARNING
Unintentional starting of the pump set
Risk of injury by moving components and shock currents!
▷
Ensure that the pump set cannot be started unintentionally.
▷
Always make sure the electrical connections are disconnected before carrying
out work on the pump set.
WARNING
Fluids handled, consumables and supplies which are hot and/or pose a health
hazard
Risk of injury!
▷
Observe all relevant laws.
▷
When draining the fluid take appropriate measures to protect persons and the
environment.
▷
Decontaminate pumps which handle fluids posing a health hazard.
CAUTION
Danger of frost/freezing
Damage to the pump set!
▷
If there is any danger of frost/freezing, remove the pump set from the fluid
handled and clean, preserve and store it.
The pump set remains installed
ü
Make sure sufficient fluid is available for the functional check run of the pump
set.
1. For prolonged shutdown periods, start up the pump set regularly once every
three months. Let it run for about one minute.
This will prevent the formation of deposits within the pump and the pump
intake area.