8 Servicing/Maintenance
32 of 56
Ama-Drainer 80/100
2331.823/07-EN
8 Servicing/Maintenance
8.1 Safety regulations
DANGER
Power supply not disconnected
Danger to life!
▷
Pull the mains plug or disconnect all electrical connections and secure against
unintentional start-up.
DANGER
Work on the pump set by unqualified personnel
Danger of death from electric shock!
▷
Have pump components modified and dismantled by authorised personnel
only.
WARNING
Fluids handled, consumables and supplies which are hot and/or pose a health
hazard
Risk of injury!
▷
Observe all relevant laws.
▷
When draining the fluid take appropriate measures to protect persons and the
environment.
▷
Decontaminate pumps which handle fluids posing a health hazard.
WARNING
Improper lifting/moving of heavy assemblies or components
Personal injury and damage to property!
▷
Use suitable transport devices, lifting equipment and lifting tackle to move
heavy assemblies or components.
8.2 Maintenance/inspection
The pump (set) is practically maintenance-free. Slight wear of the mechanical seal is
unavoidable. This will be aggravated by abrasive substances contained in the fluid
handled.
KSB recommends the following regular servicing schedule:
Table 9:
Overview of maintenance work
Maintenance interval
Maintenance work
Every 2,000 operating hours
Check the lubricant in the lubricant chamber.
Check the mechanical seal.
The operating reliability will be improved if proper functioning is checked and
verified at regular intervals (EN 12056-4).