background image

KS200-DM

OPACITY SMOKE METER

MANUAL

 (Ver. 0.4.0)

                                                                        

                                         

Содержание KS200-DM

Страница 1: ...KS200 DM OPACITY SMOKE METER MANUAL Ver 0 4 0 ...

Страница 2: ...How to install 7 3 2 precautions 7 4 Measurement Mode 7 4 1 Warm up 7 4 2 Display 8 4 3 Measurement Peak hold 9 4 4 Measurement 9 5 Select Mode 10 5 1 Key Function 10 5 2 Set Zero Span 11 5 3 Set Date 11 5 4 Set HOLD Mode 11 5 5 Set RPM 11 6 Remote Controller 12 6 1 Connet remote controller 12 6 2 How to using remote controller 12 7 Others 12 7 1 Lens 13 7 2 Probe 13 7 3 Error 13 7 4 Accessories 1...

Страница 3: ...t in a well ventilated place Install at least 25cm above the ground Notice If anything unusual occurs please stop using it immediately and contact the place of purchase or headquarters for inspection Waring Please check power before using When probe in and out watch out for burns Please install the probe in a location that is not affected by the wind Don t stay longer when the exhaust gas is gener...

Страница 4: ...KS200 DM Manual 2 Specification 2 1 Product Full Front Side Back 4 15 ...

Страница 5: ...de NO NAME Description Fan Refresh the cell with outside air INLET Gas inlet Power switch 220V 1A Fuse in it RS232 9Pin connector communication RPM RPM connector Remote control Remote control connector OIL T Oil temperature sensor connector 5 15 ...

Страница 6: ... 150 Resolution function 0 1 0 01m 1 1rpm 1 Repeatability Under 1 Response time 0 5sec 90 Preheating time Within 10 minutes Light source Green LED 565nm Detector Photodiode Optical path length 430mm Printer Built in thermal printer Power 220V AC 60Hz 100W Size 415 W 130 D 220 H excluding legs handle Weight 5 8 kg Probe 1 5m Communication RS232 4 times 1sec Option Printer RPM Oil Temperature Standa...

Страница 7: ... into the flexable probe tube and the other into the inlet of the measuring instrument and rotate the butterfly clip to fix it Connect the power 4 Measurement Mode 4 1 Warm up Power ON and start initialization Version Time Warming up within 10 min Zero Span Cal Warming up is carried out step by step and the initial count value may vary depending on the surrounding temperature or the state of use o...

Страница 8: ... Temp 25 print ex 4 3 Measurement peak hold Measurement Free acceleration mode Check whether it is selected as a peak hold Press HOLD key Insert the probe of the measuring instrument Step on the accelerator pedal The measurement screen is held at the highest value and press the PRINT key to print the held measurement value Remove the probe watch out for burns Opacity Dust Meter 2021 1 1 AM 09 00 0...

Страница 9: ...VE key choose setting value AC 1 displayed on the screen press the SET key to start the first measurement Opacity Meter Opacity Meter AC 1 0 0 m 1 rpm m 1 rpm LED is on and sound is ringing The maximum value is held and displayed Step on the accelerator pedal Press the SET key to display AC 2 on the screen and press the SET key to start the second measurement Opacity Meter Opacity Meter AC 1 0 0 r...

Страница 10: ... Judgment PASS ex Print 5 MODE 5 1 Key Function NO NAME Description SELECT Use it when choosing a menu or additional function UP Increase Value Down Decrease Value ESC Use when ending the selection mode and switching to the measurement mode SAVE Enter measurement mode and Save the data Each time you press SET key the mode changes in the order below 10 15 ...

Страница 11: ...unction 5 3 Set DATE Press the SET key in the measurement mode to move to the DATE Press the SELECT key to enter the setting mode using key set up and move on next Set up Year Date Time 5 4 Set Hold mode Press the SET key in the measurement mode to move to the HOLD Press the SELECT key to enter the setting mode using key set up and press SET key again display SAVE and move on measurement screen Pe...

Страница 12: ...ow to using remote controller Press the remote control on off key for about 3 seconds while the measuring instrument is turned on The power is turned on with the sound The measurement value are displayed on the remote control and can be operated in the same way as the operation key of the measuring instrument Press the remote control on off key for about 3 seconds to turn off the power 7 Others 7 ...

Страница 13: ...careful of burns 7 3 About error Code NO Error Check point Zr Er Sp Er It s Zero error Make sure the probe end is placed in a contaminated place Make sure the measuring cell is contaminated and wipe it clean Check and setting Zero and Span again T Er Temperature sensor error R Er RPM sensor is not connected 13 15 ...

Страница 14: ... DP 003 Probe handle Smoke probe handle DP 004 Hose band Probe hose band DP 005 Probe hose Probe hose 1 5M DP 006 Remote Control Remote Controller 10M Option DP 007 Printer Printer Option DP 008 Printer roll Printer roll 5pcs DP 009 RS 232 RS232 10M Option DP 010 Standard Filter Standard Filter 40 60 80 Option 14 15 ...

Страница 15: ...KS200 DM Manual 15 15 ...