Installation
Electrical Connection
ATTENTION
A qualified electrician must connect the main incoming power to the glasswasher in accordance
with all local codes and regulations or in the absence of local codes in accordance with the
National Electrical Code.
1.
Glasswasher is equipped with a 4
ft. power cord and plug.
2.
The power cord is prewired at the
junction box located on the front
right side of the machine behind
the lower front access panel.
3.
This model requires a
115VAC,15A receptacle.
L1
L2
115VAC
15A
4 ft. power cord w/plug supplied
DET
SANI
PRIME
START
TEMPERATURE
ON
I
O
POWER
OFF / DRAIN
R/A
The power cord is prewired to the junction box located at the lower
right-side of the machine behind the lower front access panel.
WARNING:
Electrocution or serious injury may result when working on an energized
circuit.
Disconnect power at the main breaker or service disconnect
switch before working on the circuit.
Lock-out and tag the breaker to indicate that work is being performed on
the circuit.