Troubleshooting
Troubleshooting
CONDITION
CAUSE
SOLUTION
Glasswasher will not run.
Door not closed.
Main power OFF.
Glasswasher OFF.
Close door completely.
Check breaker on panel.
Turn glasswasher ON.
Low or no water.
Main water supply off.
Solenoid valve defective.
Solenoid strainer clogged.
Flow washer defective.
Timer board defective.
Open supply valve.
Install repair kit or replace.
Clean strainer.
Replace flow washer.
Test/replace timer board.
Chemicals won’t feed into
glasswasher.
Chemical supply low.
Supply tubing damaged.
Supply tubing kinked.
Pick-up tube clogged or defective.
Timer board defective.
Refill chemical container.
Replace tubing.
Straighten tubing.
Clean/replace tube.
Test/replace timer board.
Low water pressure
pumped from spray arms.
Clogged scrap screen.
Clogged spray arms.
Clogged pump intake screen.
Clean scrap screen.
Clean spray arms.
Clean sump and pump intake screen.
Poor wash results.
Water temperature low.
Thermostat defective.
(See chemicals won’t feed above.)
(See low or no water above.)
Detergent injector defective.
Wares incorrectly loaded in dishrack.
Raise incoming watertemperature.
Adjust/replace thermostat.
(See chemicals won’t feedabove.)
(See low or no water above.)
Replace squeeze tube. Replace
injector motor. Clean pick-up tubing,
hoses and strainer.
Reposition wares/reduce amount of
wares.