13
Terminal – Machine functions
13.19 Reset bale length to zero
146
BiG Pack 1290 HDP XC
Original Operating Instructions 150000752_01_en
13.19
Reset bale length to zero
Press
for approx 2 s.
13.20
Trigger knotter
Press
.
13.21
Raising/lowering blade cassette
Release
Press
.
ð
The
and
icons are displayed.
Raising
Press and hold
.
Lowering
Press and hold
.
13.22
Setting the target bale channel flap pressure (manual mode)
NOTICE
If an excessively high target baling flap pressure is set, the machine may be
mechanically overloaded during baling. Therefore the machine may be damaged.
The display shows one of the alarm messages "Baling force exceeded" (
L>MAX
,
R>MAX
,
LR>MAX
).
If the error message "Baling force exceeded" occurs more frequently, reduce the target
bale channel flap pressure in order to prevent damage to the machine.
The bale channel flap pressure is entered by the user in manual mode. The pressure is built up
immediately if the PTO shaft is running and the machine is stopped. The pressure display
barely fluctuates on the display. To prevent damage to the machine, the bale channel flap
pressure is reduced to a non-critical value just before the system overloads. After several
seconds, the pressure set by the user is built up again. The bale channel flap pressure is
displayed in
bar
or
PSI
depending on selected system of units.
Содержание Big Pack 1290 HDP
Страница 345: ...II T P LS I III IV T P S1 S2 M1 M2 V1 V2 P1 B1 A1 B2 B1 T1 T T4 P 180 bar B36 100 bar B11 B35 150101911_00 2 4 ...
Страница 347: ...B17 K9 K11 K12 B B1 A A1 1 2 3 K13 3 4 5 1 2 150101911_00 3 4 ...
Страница 349: ...B17 K11 1 2 150101911_00 4 4 ...
Страница 351: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ ODUJH VTX XDUH EDOHU L 3 LJK 6SHHG XW 9DUL XW 3 3 1 0HGLXP RPIRUW IURP PDFKLQH QR ...