Terminal – Menus
13
Menu 1 "Knotter"
13.7
BiG Pack 1270
Original Operating Instructions 150000747_02_en
153
Display range
Pos.
Designation
Explanation
(1)
Blowing time
• In seconds.
• Adjustable value range: 0.5 - 8 s
Info:
To prevent an excessive pressure drop at
the compressed air tank, it is recommended to
first shorten the blowing interval,
Change value,
.
13.7.6
Menu 1-9 "Calibrate MultiBale"
In this menu the sensor for locking the MultiBale can be calibrated. Following repair work, a
calibration may be required due to high operational demands or settling of the components, if
the centre bar is higher or lower than the outer bars.
4,9V 0,9V 1,1V
1-9
EQ001-005 / EQ001-082
ü
Menu 1 "Knotter" has been selected,
To open the menu, press
.
Æ
The display shows the "Calibrate MultiBale" menu.
ü
The machine is shut down and safeguarded,
.
ü
The compressor unit has been filled.