![Krone Bellima F 130 Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/krone/bellima-f-130/bellima-f-130_original-operating-instructions_2004784104.webp)
11
Maintenance
11.10 Checking and setting the hydraulic tying start unit
104
Bellima F 130
Original Operating Instructions 150000148_06_en
Checking settings of distance X and Y
1
3
4
1
2
RP000-539
Place the spring rail (1) back on the setting screw (2).
Æ
The head of the setting screw (4) must be positioned on the deflection lever (3).
11.10
Checking and setting the hydraulic tying start unit
For the "Hydraulic tying start unit" version
For the "Net wrapping and twine tying" version
RP000-131
With the hydraulic start cylinder extended, the spring (2) at the hydraulic start cylinder (1) should
compress to a dimension
X=110-120 mm
.
ü
The machine is shut down and safeguarded,
.
ü
Fully extend the hydraulic cylinder for the tying start unit.
To set the dimension X, loosen the nut (3) and turn the screw until the dimension X is set.
11.11
Checking hydraulic hoses
Hydraulic hoses are subject to natural aging. This limits their service life. The recommended
service life is 6 years, including a maximum storage time of 2 years. The date of manufacture is
printed on the hydraulic hoses. When checking hydraulic hoses, the state-specific conditions
(e.g., BGVU) must be observed.
Performing a visual inspection
Visually inspect all hydraulic hoses for damage and leaks and have them replaced by an
authorised specialist if necessary.