11
Maintenance
11.8
Checking and adjusting the twine tying unit
100
Bellima F 130
Original Operating Instructions 150000148_06_en
11.8
Checking and adjusting the twine tying unit
For the "Net wrapping" or "Net and twine tying" version
11.8.1
Cleaning the twine guide slide and oiling the drive chains
RP000-136
After prolonged downtimes or if there is heavy soiling, check the twine guide slides (2) behind
the covers and clean if required.
ü
The machine is shut down and safeguarded,
.
Manually turn the drive wheel (1) anti-clockwise until the drivers (3) have completed one full
movement from the inside to the outside and back.
If the twine guide slides (2) and the drivers fail to run smoothly, clean the area:
RP000-137
Loosen the 2 covers (1) and turn them in the direction of the arrow to bring them in vertical
position as shown on the left.
Clean the twine guide slides (3), the drivers (4) and the area surrounding these components.
If necessary, oil the drive chains (2).
Close the 2 covers (1).