8
Terminal – menus [Medium Plus/Comfort Plus Electronics]
8.15
Menu 15 "Settings"
70
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
EQ001-080 / EQ001-012
ü
Menu 15 "Settings" has been selected,
.
Press
to open the menu.
Æ
The display shows the “Sensor Test” menu.
Icon
Designation
Explanation
Select previous sensor
Select next sensor
Exit menu
Setting values:
The minimum and maximum setting values with the sensor alive (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be set so that the bar is within the upper
marking in the alive state. Then check whether the bar is in non-alive state in the lower marked
area.
Possible sensors (depending on the machine configuration)
An overview of the position of the sensors and actuators is in the circuit diagram,
.
No.
Sensor
Designation
B1
B 1
Flywheel brake
B2
B 2
Blade cassette up
B3
B 3
Monitoring lubricant flow
B4
B 4
Baling ram at rear (measure)
B5
B 5
Baling ram at front (calibrate)
B6
B 6
Speed of packer
Содержание 870 HDP
Страница 380: ...FLUFXLW GLDJUDP 1 LJ3DFN EDOHU L 3 LJK 6SHHG 3 ...