Terminal – menus [Medium Plus/Comfort Plus Electronics]
8
Menu 5 "Moisture measurement"
8.11
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
57
5-2
-5
25,2
1
2
EQ001-006 / EQ001-068
ü
Menu 5 "Moisture measurement" has been selected,
.
To open the menu, press
.
Æ
The display shows the "Correction value for moisture measurement" menu.
.
Display area
Item
Designation
Explanation
(1)
Value
Measured moisture
(2)
Correction value
Adjustable value range: +10 to -10
Determining the moisture
Use an external system to determine the moisture.
Æ
If the measured value matches the value (1) on the display, everything is correct.
Æ
If the measured value does not match the value (1) on the display, correct the value on the
display.
Setting the correction value
Press
or
until the value (1) matches the measured value.
To save the value, press
.
Æ
The
icon is displayed briefly.
Æ
The value is saved.