8
Terminal – menus [Medium Plus/Comfort Plus Electronics]
8.7
Menu 1 "Knotter"
50
Supplement to Operating Instructions 150000774_00 _en
BiG Pack 870 HDP, BiG Pack 870 HDP XC
Changing mode
Call up and save mode,
8.7.4
Menu 1-4 "Blow interval"
This menu can be used to set after how many bales the knotters are blown off with compressed
air to remove dust and accumulation of crops.
1-4
3
0,5
1
1
EQ001-005 / EQ001-062
ü
Menu 1 "Knotter" has been selected,
.
To open the menu, press
.
Æ
The display shows the "Blow interval" menu.
.
Display area
Item
Designation
Explanation
(1)
Number of bales
•
Adjustable value range: 0.5 - 3 bales
•
If 0.5 is set, the knotters are blown off halfway
along the bale and at the end of the bale.
Change value,
8.7.5
Menu 1-5 "Blowing time"
This menu can be used to set how long the knotters are blown.
1-5
8s
1s
3s
1
EQ001-005 / EQ001-063
ü
Menu 1 "Knotter" has been selected,
.
To open the menu, press
.
Æ
The display shows the "Blowing time" menu.