Installation
Installation in a burner quarl
Conical burner quarl
▷
For industrial furnaces and kilns and for burning
in an open combustion chamber.
▷
Control: High/Low, continuous.
▷
Type of burner head: R.
▷
Max. capacity: 100%.
▷
We recommend the cold-air operating mode,
otherwise the nitric oxide values will be too high.
Cylindrical burner quarl
▷
For industrial furnaces and kilns and for burning
in an open combustion chamber.
▷
Control: High/Low, High/Low/Off, continuous.
▷
Type of burner head: R, H.
▷
Max. capacity: 100%.
▷
Normal to medium flow velocity.
Tapered burner quarl
▷
For industrial furnaces and kilns and for burning
in an open combustion chamber.
▷
Control: High/Low, High/Low/Off, continuous.
▷
Type of burner head: H.
▷
Max. capacity: approx. 80%, depending on the
outlet diameter of the burner quarl.
▷
Medium to high flow velocity.
Flat flame burner quarl
▷
For industrial furnaces and kilns and for burning
in an open combustion chamber.
▷
Control: High/Low, High/Low/Off, continuous
(limited control range).
▷
Type of burner head: K.
▷
Capacity range: 40 – 100%.
Burner with attachment tube
▷
Position of the burner head near the interior fur-
nace wall (
L
= L
O
± 50 mm).
L
2
= L
O
± 50 mm
L
O
1
▷
Do not fit the attachment tube
directly in the
furnace wall.
▷
Furnace temperature ≤ 600°C.
Radiant tube heating:
▷
Reduce the outlet diameter of the radiant tube
using an orifice
to the point where a pressure
loss of approx. 10 mbar occurs at the burner’s
rated capacity.