GB-2
D
GB
F
NL
I
E
Checking the usage
Burner for heating industrial thermoprocessing equip-
ment. For installation in a burner quarl or for use
with an extended, heat-resistant burner tube. For
natural gas, town gas and LPG. Other types of gas
on request.
This function is only guaranteed when used within
the specified limits – see also page 12 (Technical
data). Any other use is considered as non-compliant.
Construction stage, rated capacity Q
max
, gas type –
see type label.
D-49018 Osnabrück Germany
ZIO 165HB-100/35/18/D
BR 84246114
Qmax 630 kW Gas N SN
BR 74970471 BK
18
D
1114
Type code
Code
Description
ZIO
ZIOW
Burner for gas
Burner for gas with internal
insulation
65 – 00
Burner size
R
H
K
Normal flame
Long, soft flame
Flat flame
B
D
G
M
Natural gas
Coke oven gas, town gas
Propane, propane/butane, butane
Propane, propane/butane, butane
L
Ignition lance
-50
-00
-50
-00
...
Burner tube length [mm]
/5-
/5-
/5-
...
Position of burner head [mm]
-() to -(99)
-(E) to
-(99E)
Burner head identifier
High temperature version
A to Z
Construction stage
Z
Special version
Part designations
1
3
4
5
6
8
2
7
Burner insert
Gas housing gasket
Air housing
4
Burner tube gasket
5
Burner tube with mounting flange
6
Mounting gasket
7
Type label
8
Enclosed documentation (flow rate curves,
operating characteristic diagrams, dimension
sheet, spare parts list, spare parts drawing
and Declaration of Incorporation)
•
Check letter marking and identification marks on
the burner head using the information provided
on the type label.