Mechanical data

Dimensions (W × H × D):
96 × 63 × 23 mm (3.78 × 2.48 × 0.91 inch).
Weight: 0.3 kg.

Electrical data

Power consumption: 1.2 VA.
Power loss: 0.7 W.

Designed lifetime

Max. service life under operating conditions:
20 years after date of production.

Logistics

Transport

Protect the unit from external forces (blows, shocks, 
vibration). 

Transport temperature: see page  5 (Technical 

data). 

Transport is subject to the ambient conditions de-

scribed. 
Report any transport damage on the unit or packag-
ing without delay. 
Check that the delivery is complete, see page 
(Part designations).

Storage

Storage temperature: see page 5 (Technical data). 
Storage is subject to the ambient conditions de-
scribed. 
Storage time: 6 months before using for the first 
time. If stored for longer than this, the overall service 
life will be reduced by the corresponding amount of 
extra storage time.

Packaging

The packaging material is to be disposed of in ac-

cordance with local regulations.

Disposal

Components are to be disposed of separately in 
accordance with local regulations.

Certification

ODVA compliant

Scan of the Declaration of conformity (GB) – see 
www.docuthek.com

PROFIBUS User Organization

The PROFINET IO device BCU 4xx with BCM 400 has 

successfully passed the certification tests, according 
to certificate No. Z12594.

Содержание BCM 400 B2 Series

Страница 1: ...uations WARNING Indicates possible danger to life and limb CAUTION Indicates possible material damage All interventions may only be carried out by qualified gas technicians Electrical interventions may only be carried out by qualified electricians Conversion spare parts All technical changes are prohibited Only use OEM spare parts Changes to edition 04 19 The following chapters have been changed C...

Страница 2: ...trol via bus Part designations 4 5 2 3 7 8 1 1 BCM 3 with RJ45 sockets 2 RJ45 socket port P1 for connecting to the bus communications system 3 RJ45 socket port P2 for connecting to the bus communications system 4 Green LED to indicate a connection off no connection on connection flashing data transfer 5 Yellow LED to indicate the transfer rate on 100 Mbit off 10 Mbit 7 Code switches 8 Type label M...

Страница 3: ...s may only be allocated once within the fieldbus system PROFINET a device within the fieldbus system can be identified using the subscriber flash test display shows 00 with alternately highlighted segments For instructions on commissioning the control unit see operating instructions Burner control unit BCU 46x 480 If the fault message 1 to 4 flashes in the control unit s display fieldbus communica...

Страница 4: ...et on the code switches must be identical to the address xxx entered in the automation system s network configuration After the code switch settings have been changed the control unit must be switched off and on again to enable the new address setting 5 Start the network communication The BCU powers up If the IP address is valid the program can be started Parameter A080 2 Fieldbus communication wi...

Страница 5: ...assigned in the engineering tool or replace it with an individual name e g Furnacezone1 Check whether the device name name in the network configuration is the same as the device name saved in the control unit Check the value of parameter A080 and adjust it if necessary 4 The display on the control unit blinks and indicates 4 The controller is set to Stop Start the controller E E The display on the...

Страница 6: ...ee page 5 Technical data Transport is subject to the ambient conditions de scribed Report any transport damage on the unit or packag ing without delay Check that the delivery is complete see page 2 Part designations Storage Storage temperature see page 5 Technical data Storage is subject to the ambient conditions de scribed Storage time 6 months before using for the first time If stored for longer...

Отзывы: