background image

 

 

 
 
 
 

LCD-TFT Monitors 

LM5000 

 
 
 
 

User Manual 

LM5000D11-02 

 
 

 
 

Edition 03

 

 

March 2004  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

KROMA

 

T E L E C O M 

 

Pol. Ind. Alcobendas - C/ La Granja, 80 

28108  Madrid - SPAIN 

Tel. (34-91) 661 45 14 

Fax. (34-91) 484 03 49 

e-mail: 

[email protected]

 

www.kromatelecom.com

 

 

 

Содержание LM5009

Страница 1: ... LM5000 User Manual LM5000D11 02 Edition 03 March 2004 KROMA T E L E C O M Pol Ind Alcobendas C La Granja 80 28108 Madrid SPAIN Tel 34 91 661 45 14 Fax 34 91 484 03 49 e mail sales kromatelecom com www kromatelecom com ...

Страница 2: ...EMORY RECALL MENU 11 4 3 SETUP MENU 12 4 3 1 SETUP MENU MANUAL 13 4 3 1 1 CALIBRATION VALUES MENU 14 4 3 1 2 GEOMETRY SETUP MENU ONLY FOR RGB VIDEO SIGNAL 15 4 3 1 3 COLOUR SETTING MENU 16 4 3 1 4 CAL WITH ACTIVE DATA 17 4 3 1 5 SYSTEM OPTIONS CONFIGURATIONS MENU 17 4 4 PASSWORD MENU 19 4 4 1 EXPLANATION ON THE PASSWORDS 20 4 5 TECHNICAL MENU 20 4 6 MEMORY STORE MENU 21 4 7 PROGRAM FUNCTION MENU 2...

Страница 3: ...rie LM5000 2 1 1 F FR RO ON NT T P PA AN NE EL L LM5009 LM5015 LM5018 LM5018 LM5018 A The equipment Switch on Switch off B Calibration Diode C Optical Encoder D Keyboard E Tally Led Indicator C A B C D E A B D E E A B C D ...

Страница 4: ...ignal NTSC Brightness and Contrast for SDI RGB PC video signal Optical Encoder The optical encoder serves to move through the different menus that the system offers and to change values of the system Moving the optical encoder in clock wise direction a value will be increased or the window of selection in the menus Moving it in opposite sense a value will be decreased or the window of selection Ke...

Страница 5: ...rial Number Power Supply C AES EBU Audio Output optional D Analog Audio Output optional E Tally Input Indicator F Connection with the Remote Equipment G Composite Video Inputs A B optional H SDI Video Inputs S1 S2 optional I RGB PC Input optional A B C E D F G H I A B E C D F G I H A B C D E F G H I ...

Страница 6: ...ed into the equipment Tally Input Indicator It allows to indicate the active screen Connection with the Remote Equipment Optionally the TFT Monitors series LM5000 have a remote equipment RK5000 that allows to control the screens remotely Composite Video Inputs The equipment can have two inputs CCVS A and CCVS B in composite video it admits video signal in PAL NTSC or SECAM SDI Video Inputs The equ...

Страница 7: ...d the second and the successive ones will cause a change of video input If the CCVS option is installed will appear an indicative text on the screen it will show the input selected in each time and the presence or absence of signal in the same one If the CCVS option is not installed it will appear a message of absence of the CCVS option After few seconds or pressing the ESC key such message will d...

Страница 8: ... few seconds or pressing the ESC key such message will disappear automatically BLK Brightness Control on the screen Once this key is pressed it will show the screen current value of brightness and if it agrees with the calibrated value CAL if not UNCAL By means of the optical encoder C in the front part this value will be able to be changed Pressing the CAL key the brightness value will be calibra...

Страница 9: ...the two keys is that key AUD can be configurated as volume control while the CHN can not due to on LM5015 and LM5018 equipments there is an associated key for this function VOL STS Access to the system menus ESC To cancel an operation or to abandon a certain operation CAL It allows to return to the calibrated value or to select an option from the system menus SIZE Screen aspect ratio 4 3 or 16 9 T...

Страница 10: ...ds or to introduce numeric data For example the equipment network identifier ID It is not neccesary to wait a text disappear for pressing another key Automatically the associated operation will be executed to the second pressed key 4 4 M ME EN NU US S The access to the menus is made through STS key located in the front panel The STATUS menu is the main one of the system From this status menu it is...

Страница 11: ...ositive sense to increase the position of the selection window Next press CAL key then it will accede to this menu If the user wants to leave from the menus application the ESC key will be pressed and then it will disappear Pressing for one second time STS key it appears a submenu denominated CONFIGURATION VALUES with the following aspect ...

Страница 12: ...e versions could be updated For that reason contact your supplier SYSTEM It indicates if there is any Hardware error If there is not any error it will appear an OK In the opposite case it will appear an error code In this case you must contact your supplier in order to solve the possible problems and to avoid the non operation system FPGA VERSION It indicates the system FPGA configuration version ...

Страница 13: ...ut groups and AES EBU channels output Geometry Values h shift v shift h soc etc Menu Values PROGRAM FUNCTION In order to recall a memory it will be enough locating the selection window in the wished one by means of the optical encoder C in the front part and pressing the CAL key Then it will appear a text showing the recally progress and if this has been made successfully or not DONE ERROR User 1 ...

Страница 14: ...password In this way it is avoided that the screen values can be modified by a nonauthorized user The password that is requested for as can be verified is the one from the SYSTEM which one will be introduced after pressing the CAL key by means of the keyboard Remember that upon each key exist the equivalent of each one in numerical format If the password is correct it will be acceded directly to t...

Страница 15: ...calibration value C of the control that is desired to modify In order to change a value in the first place we will select by means of the optical encoder C in the front panel and after to press the CAL key Access Sequence The selection will be marked in red By means of the optical encoder the value is varied Pressing CAL key once again the new value will be validated Pressing ESC key it will be re...

Страница 16: ...tal Sync of the RGB signal V POLARITY Vertical Sync of the RGB signal Each option of the menu is independent for each type RGB resolution so we can have defined a horizontal position a resolution of 640x480 60Hz and another one of 800x600 60Hz In order to adjust a value it must be selected by means of the optical encoder C in the front panel and finally press the CAL key Value Modification Sequenc...

Страница 17: ...MENU Access Sequence The COLOUR SETTING Menu allows to shift each RGB colour component In order to adjust one of these values it must be selected by means of the optical encoder C in the frontal panel and then press CAL key Value Modification Sequence By means of the optical encoder this value could be changed Pressing the CAL key the new value will be validated or approved ...

Страница 18: ...The option CAL WITH ACTIVE DATA allows to calibrate the equipment with the current values For that it is neccesary to select the option by means of optical encoder C in the front panel and to press the CAL key Secuencia de calibración del equipo Then it will appear a text showing the recally progress and if this has been made successfully or not DONE or ERROR Pressing the ESC key it will return to...

Страница 19: ...t the steps to follow are 1 Contact your distribuitor and let him know the equipment serial number Then the activation code will be facilitated provided 2 Once you know such code it is acceded to the menu and by pressing CAL key it will be introduced 3 If the introduced code is correct the equipment will be reinitiated automatically so the option will be activated In opposite case it will give an ...

Страница 20: ... is requested for to assure that it cannot be changed by any other person Old Password Request As it is possible to be observed in the menu headline above it appears the user who is going to change the password If the introduced old password is correct it will become to change the password In the opposite case it will give an error message and it will become to the initial state of PASSWORD menu I...

Страница 21: ...ne will stay Finished the process automatically it will become to the PASSWORD menu In order to leave this PASSWORD menu and return to the STATUS menu it will be necessary to press the ESC key Initially all the codes passwords are initialized with values 1234 from factory Access Sequence The TECHNICAL menu is of restricted access The KROMA TELECOM technicians will be only able to accede to this me...

Страница 22: ...nalog channels output groups and AES EBU channels output Geometry Values h shift v shift h soc etc Menu Values PROGRAM FUNCTION It is necessary to remark that the technical memory cannot be modified In this way the technical values in the equipment will be able to be always recovered On the other hand the option all memories ALL MEM only can be used by the technicians In order to store the values ...

Страница 23: ...o store the values that the system has at the moment in the memory of corresponding user In the opposite case it will become to the initial state of MEMORY STORE menu Then it will appear a text showing the recally progress and if this has been made successfully or not DONE or ERROR Storing Sequence In order to leave the MEMORY STORE menu the ESC key will be pressed Access Sequence LM5009 LM5015 y ...

Страница 24: ...origin signal it will establish nominal values for the signal when it is presenting displaying on the screen It is only for composite video signal In order to modify the AGC press the CAL key COLOUR Colour of the picture It is only for composite video signal It can have the AUTO value so such picture would have the colour adjusted in the saturation or it could be MONO so the picture would be displ...

Страница 25: ... a new menu LM5009 LM5015 and LM5018 A function will be chosen from AUD or CHN key upon in one of them the CAL key will be pressed so it will be returned to PROGRAM FUNCTION menu If we do not want to modify the current function then the ESC key In both cases it will return to PROGRAM FUNCTION menu In LM5015 LM5018 equipments do not appear the volume control option because they have a key associate...

Страница 26: ...at group and channel Example A red asterisk indicates presence of STEREO audio and a white asterisk indicates presence of MONO audio The output audio selection in Analog and AES EBU case is made by pairs of channels 1 2 and 3 4 selecting the wished group In the example we can see that there are audio in channels 1 2 3 4 and groups 1 2 This audio is MONO in group 1 and STEREO in group 2 For example...

Страница 27: ... In this case we have selected channels 1 and 2 1 2 belong to group 1 for the AES EBU output The process would be exactly the same one to make a selection of analog audio output D in the rear panel and for any audio group and pair of channels The audio update in this menu is done in a continuous way In order to leave this menu press the ESC key Access Sequence 4 9 MENU REMOTE ...

Страница 28: ... the CAL key must be pressed and then to introduce the new identifier by means of the keyboard ID Network Modification If the modification is correct will appear the message OK In opposite case an error has been generated The operations that the remote equipment allows to make on series LM50XX are the same ones that allows each equipment through its keyboard By defect the network identifier will b...

Отзывы: