Страница 2: ...u in sweep mode 13 10 4 1 Stepped sweep 14 10 4 2 Sweep on list 15 10 5 User settings menu 16 10 6 Additional options menu 17 10 7 Setting the time to automatically turn off the screen 18 10 8 Externa...

Страница 3: ...the wires by pulling the cord 2 1 4 Persons using the device are strictly prohibited pass the device to strangers disassemble and carry out any repairs not agreed with the manufacturer use a device w...

Страница 4: ...rence signal source Connector type SMA female Input frequency range 10 40 MHz Input signal level maximum 13 dBm recommended 5 10 dBm Input impedance 50 Ohm External trigger Connector type SMA female M...

Страница 5: ...3 2 Figure 3 1 Maximum output power level of the ARINST ArSiG S generator Figure 3 2 Maximum output power level of the ARINST ArSiG R generator 3 3 Spectral purity Measurements were made with an outp...

Страница 6: ...5 9 500 34 9 1000 24 4 2000 16 7 8 3000 21 21 4000 31 36 5000 36 36 6000 40 45 6200 50 47 3 3 3 Phase noise Table 5 Frequency MHz ARINST ArSiG S Offset from carrier 1 kHz 10 kHz 100 kHz 1 MHz SSB phas...

Страница 7: ...70 dB typ 70 dB typ 100 70 dB typ 70 dB typ 1000 70 dB typ 70 dB typ 3000 70 dB typ 70 dB typ 5000 60 dB typ 30 dB typ 6000 60 dB typ 35 dB typ Minimum pulse width 1000 s typ Minimum pulse period 200...

Страница 8: ...ed by dividing the set frequency of the voltage controlled oscilla tor VCO Comparing the obtained value with the frequency of the reference oscillator and adjusting the VCO with a voltage proportional...

Страница 9: ...tput signal Thus the output signal is sinusoidal Then the generated signal is fed to the power amplifier The ampli fied signal is fed to the output connector Also with the help of a power coupler the...

Страница 10: ...off the device press and hold the button 6 for about 2 seconds The screen 4 of the in strument will turn off and the instrument will turn off Each time the device is turned off the current user setti...

Страница 11: ...ency setting buttons and moving the cursor over the digits of the set frequency value or output sig nal power level and decrease or increase in the frequency or power level of the output signal 8 2 2...

Страница 12: ...utput frequency 10 1 1 To set the output frequency press the button on screen interface of the device 10 1 2 In the submenu that opens Fig 10 1 enter a numeric value for the output frequency and click...

Страница 13: ...Hz Duty cycle fill factor Depends on the set values of the period and pulse width MOD OFF MOD ON modulation off on BACK exit the menu 10 3 3 The parameters are set by entering a numerical value in th...

Страница 14: ...er of points in the frequency interval and the less time it takes to cycle On the contrary the smaller the frequency step the more points and the longer the process takes Buttons for setting steps Ste...

Страница 15: ...creating a list of sweeps 10 4 2 3 Buttons for working with the list of sweeps add the sweep element to the list Go to the menu Add new sweep record New sweep entry Fig 10 6 edit the selected element...

Страница 16: ...77 Figure 10 7 User settings menu 10 5 2 User settings menu buttons Save the current settings Go to the menu to assign the name of the setting Figure 10 8 edit the name of the highlighted custom sett...

Страница 17: ...ter the additional Settings menu by pressing the button on the device screen The additional options menu is shown in Figure 10 9 Figure 10 9 Menu of additional options 9 6 2 This section of the menu c...

Страница 18: ...nce frequency source The device can use both an internal and an external signal as a reference signal The external refer ence signal is fed to the REF IN input located on the right panel of the genera...

Страница 19: ...he power level offset is shown in parentheses in the power field of the device Figure 10 10 Figure 10 10 Signal power level offset enabled 10 12 Changing the theme of the on screen interface The devic...

Страница 20: ...llowed to operate while the battery is charging provided that the power supply is capable of providing an output current of at least 1500 mA If the charger or the USB port of the PC is not able to pro...

Страница 21: ...in reverse order 11 3 8 After assembling the device charge the battery in accordance with paragraph 11 2 11 4 Storage 11 4 1 Before putting into operation the device must be stored in the manufacture...

Страница 22: ...evice is not allowed recovery to a healthy state is impossible or economically impractical 11 6 2 Upon reaching the limit state the device must be decommissioned and disposed of 11 7 Utilization 11 7...

Страница 23: ...Operate the device at an ambient temperature of 0 to plus 40 C The screen is dirty Clear the screen Faulty on screen device module Contact a service center for re pair 5 No RF signal from RF OUT The...

Страница 24: ...ects of the Goods caused by the influence of virus programs interference with the software or the use of third party software non original the defect is caused by force majeure for example earthquake...

Страница 25: ...dded that ex pands the scope of the device We recommend that you regularly update the device firmware 1 Installing the boot loader and virtual port driver on your PC 1 1 Go to the official website of...

Страница 26: ...instructions of the installer The Arinst Firmware Updater application and the virtual COM port driver will be installed The installer package contains all the necessary components for the correct oper...

Страница 27: ...efresh button 2 6 After selecting the COM port connect the device by clicking the Apply button 2 7 After connection the ID and firmware version of the device will be determined The Check for updates b...

Страница 28: ...update the device firmware manually click the Upgrade firmware button If the device was in application mode it will automatically restart during the firmware update The ap plication message will be d...

Страница 29: ...e the application will display the latest installed version of the device software Figure A2 7 Figure A2 7 Displaying the device firmware version To ensure that the latest firmware is installed click...

Страница 30: ...are again Figure A3 2 Unsuccessful firmware download 3 3 If the update process was interrupted the device will start in update mode until the update pro cess is completed The device displays a message...

Страница 31: ...rmware If the checksums do not converge a mismatch message is displayed on the screen Figure A3 4 After rebooting the de vice will be in the update error mode Check the connection of the device to the...