Страница 1: ...Supplementary Instructions for IECEx applications Supplementary Instructions for IECEx applications OPTIWAVE 5200 C F OPTIWAVE 5200 C F OPTIWAVE 5200 C F OPTIWAVE 5200 C F Supplementary instructions...

Страница 2: ...s pressure 17 3 Electrical connections 18 3 1 General notes 18 3 2 Terminal compartment 18 3 2 1 How to open the terminal compartment 18 3 2 2 How to close the terminal compartment 19 3 3 Terminal tig...

Страница 3: ...OPTIWAVE 5200 R03 en OPTIWAVE 5200 C F 5 Service 29 5 1 Periodic maintenance 29 5 2 Keep the device clean 29 5 3 Returning the device to the manufacturer 29 5 3 1 General information 29 5 3 2 Form for...

Страница 4: ...nline help functions The level transmitter is approved for use in potentially explosive atmospheres when equipped with the appropriate options 1 3 Standards and approvals INFORMATION The information i...

Страница 5: ...es in Gas Groups IIA IIB and IIC when fitted with the appropriate options It is certified for applications for which an EPL of Ga Gb or Gb is necessary The Ex ia tb approved device is suitable for use...

Страница 6: ...output option Ex ia or Ex ic approvals 4 20 mA passive HART output option Ex ia or Ex ic approvals Intrinsically safe circuit data 4 20 mA passive HART output option Ex d ia or Ex ia tb approvals 4 20...

Страница 7: ...version 1 Approval logo 2 IECEx certification agency code 3 Types of device protection including approved Gas Groups temperature classes T6 T4 or T3 or T2 depends on the antenna type and equipment pro...

Страница 8: ...plosive atmospheres Part 14 Electrical installations design selection and erection and IEC 61241 14 Electrical apparatus for use in the presence of combustible dust Part 14 Selection and installationT...

Страница 9: ...ranges in the Installation chapter of the handbook Figure 2 1 ESD warning sticker below the device nameplate 1 Text Plastic Parts 2 Text Warning Potential electrostatic hazard see instructions PLASTIC...

Страница 10: ...ignal converter process connection and antenna 2 Remote Field version remote converter 3 Remote Field version antenna housing process connection and antenna WARNING Compact version only If the device...

Страница 11: ...ic Horn Wave Guide standard temperature Metallic Horn Wave Guide high temperature C F C F C F C F C F T6 46 115 46 115 46 115 46 115 45 113 T5 41 106 42 108 41 106 44 111 55 131 T4 38 100 40 104 39 10...

Страница 12: ...0 104 44 111 43 109 54 129 100 212 T4 77 171 77 171 77 171 79 174 85 185 69 156 71 160 70 158 76 169 110 230 57 135 54 129 71 160 135 1 275 1 T3 50 122 48 118 68 154 150 1 302 1 64 147 180 1 356 1 61...

Страница 13: ...C F T6 46 115 46 115 46 115 46 115 45 113 T5 41 106 41 106 41 106 44 111 55 131 T4 39 102 39 102 39 102 43 109 60 140 Temperature class Minimum ambient temperature Min flange temperature PP Wave Horn...

Страница 14: ...1 110 230 55 131 53 127 72 162 135 1 275 1 T3 48 118 45 113 66 151 150 1 302 1 63 145 180 1 356 1 57 135 200 1 392 1 T2 53 127 250 1 482 1 1 Make sure that gasket temperature is in the specified limit...

Страница 15: ...ent temperature PP Wave Horn PTFE Wave Horn and Wave Stick Compact version Remote Field version Compact version Remote Field version C F C F C F C F C F 80 176 80 176 80 176 80 176 80 176 90 194 75 16...

Страница 16: ...te Field version Compact version Remote Field version C F C F C F C F C F 80 176 80 176 80 176 80 176 80 176 90 194 75 167 75 167 78 172 79 174 100 212 71 160 70 158 77 171 77 171 110 230 66 151 65 14...

Страница 17: ...ory 1 2 D 2 D 3 D or EPL Da Db Db Dc Ex ia Ex ia tb and Ex ic devices only Equipment category 1 2 D 2 D 3 D or EPL Da Db Db Dc Ex ia Ex ia tb and Ex ic devices only Equipment category 1 2 D 2 D 3 D or...

Страница 18: ...ntry size refer to the device nameplate If ambient temperature 65 C 149 F use heat resistant cables cable glands and cable entry plugs certified for continuous operation above 80 C 176 F WARNING If di...

Страница 19: ...carefully to prevent damage to the thread and the gasket Make sure that the terminal compartment cover is tight Use a 2 5 mm Allen wrench to attach the cover stop 1 Make sure that the cover stop 1 sc...

Страница 20: ...g conductor Connect the device to the equipotential bonding system for the hazardous location Remote Field version There is a terminal on the wall support and a terminal at the bottom of the antenna h...

Страница 21: ...l circuit characteristics are not more than the values that follow Do not remove more than 6 mm 0 2 of insulation from the wire 3 5 2 Maximum intrinsically safe values for the electrical circuit 3 5 3...

Страница 22: ...smitter with the 4 20 mA passive HART output option Figure 3 5 Electrical schematic for Ex ia approved equipment with the 4 20 mA passive HART output option Level transmitter with the FOUNDATION field...

Страница 23: ...tment are Ex ia approved and the terminals compartment is Ex d Ex t approved Figure 3 7 Compact version Compartments in Ex d ia and Ex ia tb approved equipment Figure 3 8 Remote Field version Compartm...

Страница 24: ...circuit on page 21 3 6 4 Electrical schematic WARNING Use only Ex d approved cable entries and plugs for Ex d applications Use only Ex t approved cable entries and plugs for Ex t applications Do not r...

Страница 25: ...n Figure 3 10 Electrical schematic for Ex d ia Ex ia tb approved equipment without galvanic isolation 1 Galvanically isolated power supply 2 Power supply 3 Resistor for HART communication 4 Non Ex zon...

Страница 26: ...cteristics are not more than the values that follow Do not remove more than 6 mm 0 2 of insulation from the wire 3 7 2 Maximum intrinsically safe values for the electrical circuit 3 7 3 Supply voltage...

Страница 27: ...speak to the supplier Level transmitter with the 4 20 mA passive HART output option Figure 3 12 Electrical schematic for Ex ic approved equipment with the 4 20 mA passive HART output option Level tra...

Страница 28: ...applications Ex ia applications Ex ia applications Are you using an intrinsically safe barrier within the correct parameters For more data refer to Ex ia equipment on page 21 The electrical circuit ch...

Страница 29: ...ollowing points Due to statutory regulations on environmental protection and safeguarding the health and safety of our personnel manufacturer may only handle test and repair returned devices that have...

Страница 30: ...al no The device has been operated with the following medium This medium is radioactive water hazardous toxic caustic flammable We checked that all cavities in the device are free from such substances...

Страница 31: ...NOTES 6 31 OPTIWAVE 5200 C F www krohne com 09 2014 4001906103 AD IECEX OPTIWAVE 5200 R03 en...

Страница 32: ...lysis products Products and systems for the oil gas industry Measuring systems for the marine industry Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 F...