background image

 

 

 

OPTIFLUX  

6000

 

Electromagnetic 

Hygienic Flow Sensor

 

 

Flanged and adapter versions 

   

 

for volumetric flowrate measurement 
of electrically conductive liquids

 

   

 

     

 

   

General 

   

Items supplied 

 

     

 

For in-depth information please consult 

the handbook, data sheet, special 

manuals and certificates supplied on  

CD-ROM. 

   

 

   

 

Installation, assembly, commissioning and 

servicing must only be undertaken by 

trained personnel. Maintenance which is 
considered relevant to safety in the sense 

of explosion protection must only be 

carried out by the manufacturer, his 

agents or under the supervision of 
experts. 

   

 

 

 

     

   

Visual check 

     

   

  Example 

 

   

 

 

 

 

For use in hazardous areas, special 

codes and regulations are applicable, 
which are supplied in a separate 

document that describes all hazardous 

area relevant information. 

   

 

Responsibility as to suitability and 
intended use of this device rests solely 

with the user. The supplier does not 

accept any liability resulting from misuse 

by the customer. Improper installation and 
operation may lead to loss of warranty. In 

addition, the "General conditions of sale", 

found on the back of the invoice and 

forming the basis of the purchasing 
contract, are applicable. 

   

 

 

 

 

   

 

 

 

If you need to return the device to the 

manufacturer or supplier, please complete 

the form given on the CD-ROM and attach 
it to the device. KROHNE regrets that it 

cannot repair or check your device unless 

accompanied by this completed form. 

     

Only separate version 

JS 

© KROHNE 03/2006                          7.30954.31.00 

Liner materials 

  Electrode materials 

 PFA   Teflon-PFA 

  HC4 

Hastelloy C4 

 V4A 

Stainless 

steel 

  
  

 Ti 

Titanium 

 

Quick Start

 

Содержание OPTIFLUX 6000

Страница 1: ... supplied in a separate document that describes all hazardous area relevant information Responsibility as to suitability and intended use of this device rests solely with the user The supplier does not accept any liability resulting from misuse by the customer Improper installation and operation may lead to loss of warranty In addition the General conditions of sale found on the back of the invoic...

Страница 2: ...Quick Start OPTIFLUX 6000 2 OPTIFLUX 6000 Handling and installation instructions ...

Страница 3: ...C 300 40 C 140 C IFC 300 40 F 284 F PFA 40 C 180 C IFC 010 25 C 120 C PFA 40 F 356 F IFC 010 13 F 248 F Ambient temperatures Ambient temperatures C min max F min max IFC 300 40 C 65 C IFC 300 40 F 149 F IFC 010 25 C 60 C IFC 010 13 F 140 F Note The min max temperatures for the compact devices are dependent on the liner converter combination and the used type of adapter See data sheet ...

Страница 4: ...Quick Start OPTIFLUX 6000 4 OPTIFLUX 6000 Special considerations ...

Страница 5: ...m the adapters by loosen the screws as well as the L shaped gaskets 3 Weld the adapters completely to the pipe 4 After the pipe has cooled down reinstall the gasket and mount the flowmeter Grounding Metal pipelines not internally coated Grounding without grounding rings Metal pipelines with internal coating and internally non conductive pipelines Grounding with grounding rings Grounding rings Clea...

Страница 6: ... 8 115 120 248 Clamp joint to ISO 2852 125 150 5 72 120 248 DN 25 50 16 230 140 284 Clamp joint to DIN 32676 DN 65 100 10 145 140 284 3 20 5 295 120 248 Clamp joint to TRI CLOVER 4 13 8 200 120 248 Vacuum load all versions and sizes 0 mbar abs 0 psia for meter size DN 2 5 DN 10 separate flow sensor max temperature up to 150 ºC 302 ºF Pressure rating and max torque for 11864 2A flange version Nomin...

Страница 7: ...7 Quick Start OPTIFLUX 6000 OPTIFLUX 6000 ...

Страница 8: ...al Area H Block Pimpri Poona 411018 TEL 91 0 202 7442020 FAX 91 0 202 7442020 e mail pcu vsnl net Iran KROHNE Liaison Office North Sohrevardi Ave 26 Sarmad St Apt 9 Tehran 15539 TEL 98 21 874 5973 FAX 98 21 850 1268 e mail krohne krohneiran com Italy KROHNE Italia Srl Via V Monti 75 I 20145 Milano TEL 39 0 2 4 30 06 61 FAX 39 0 2 43 00 66 66 e mail info krohne it Korea KROHNE Korea Room 508 Miwon ...