Insufficient current intensity
If there are too many collectors in your
proximity connected to the network at the
same time, the available voltage and the
current intensity may decline. Consequent-
ly the motor of the high-pressure cleaner
does not start or even blows.
The power supply may also be insufficient
if the power cable is too long or too thin. If
extension cables are too long, this may
lead to a voltage drop causing malfunct-
ions or start-up difficulties.
Connected load: 400 V, 12 A, 50 Hz
Electrical connection
The machine is supplied with an electrical power cable with plug. The mains plug must
be fitted to a standard grounded socket with a
30mA
residual current operated device.
The socket must be protected with a
16A delay action fuse
on the mains side.
Kränzle
quadros: 400 Volt, 50 Hz
. When using an extension cable, this must have an earthed
lead which is properly connected to the socket. The conductors in the extension cable
must have a minimum cross section of
1.5 mm²
. Plug connections must be of a spray-
proof design, and may not be located on a wet floor. With extension cables of
more than
10 m
the minimum cross section must be
2.5 mm
! When using a cable drum, always
keep the cable wound as far as possible.
Check the line fusing and have the voltage and the available
current intensity checked by an expert in case of uncertainty.
12
That's what you have to observe!
Содержание quadro 1500 TS
Страница 32: ...Spare parts list quadro 1500 TS TST Complete assembly 32...
Страница 36: ...Spare parts list Kr nzle quadro 1500 TS TST Pump motor 36...
Страница 38: ...Spare parts list Kr nzle quadro 1500 TS TST Pump transmission unit for AQ pump 38...
Страница 40: ...Spare parts list Kr nzle quadro 1500 TS TST Unloader valve and pressure switch 40...
Страница 44: ...Spare parts list Kr nzle quadro 1500 TS TST Hose drum 44...