General rules

This is prohibited !

Never direct the
water jet at
people or animals !

Do not damage
the power cord
or repair it
incorrectly !

Inspections:

The machine must be inspected according to the "Guidelines for Liquid
Spray Devices" at least once every 12 months by a qualified person, to
ensure that continued safe operation is guaranteed. The results of the
inspection are to be recorded in writing. This may be done in any form.

Accident prevention

The machine is designed for accidents to be impossible if used correctly.
The operator is to be notified of the risk of injury from hot machine parts and
the high pressure water jet. The "Guidelines for Liquid Spray Devices" must
be complied with. (See page 13 + 14)
Please pay attentions to the regulations of your waterworks company.
(Reflux valve with tube ventilation according to DIN 1988)

Check the oil level at the oil sight glass prior to each use.
(Ensure horizontal position !)

Oil change:
No oil change is required during the working life of the machine. We would
suggest though to change the oil after having used the high pressure clea-
ner for a longer period of time to ensure its longevity. Should it be necessary
to change the oil the oil sight glass is to be opened over a reservoir and the
machine to be emptied. The oil is to be caught in the reservoir and disposed
of in the approved manner.
New oil: 0,25 l - Motor oil W 15/40

Never pull the high
pressure hose if it has

formed kinks or "nooses" !

Never pull the hose

over sharp edges !

Warranty

This warranty covers material and/or workmanship related defects only and does
not extend to ordinary wear.

Machine must be operated according to enclosed operating instructions which are
part of present warranty conditions.

All products sold directly to private customers are warrantied for a period of 24
months, whereas the warranty period for industrial purchases is limited to 12
months.

In case of any warranty claims, please have your HP cleaner together with
accessories and your purchase document ready and contact your nearest dealer or
authorized service point which can also be looked up in the internet at
www.kraenzle.com .

Warranty is void in case of attempts to modify any of the safety devices or in the
event of exceeding temperature or rpm limits - this also applies to undervoltage, low
water and/or polluted water. Gauge, nozzle, valves, sealing gaskets, high pressure
hose and spray equipment are considered wear parts and do not fall under this
warranty.

Содержание junior 120

Страница 1: ...High pressure cleaner Reproduction only by permission of Date 18 06 2004 Operating instructions Read and confirm before use 110 115 V 60 Hz 95 bar R...

Страница 2: ...water input electrical ratings connected input wattage output fuse protection weight dimensions sound level accord to DIN 45 635 with dirtkiller recoil at lance torque Kr nzle junior 120 95 bar 110 b...

Страница 3: ...ir release valve with reflux valve Item 1 Water inlet connection with a filter 2 Suction hose with filter special accessory 3 High pressure pump 4 Pressure gauge 5 High pressure hose 6 Spray gun assem...

Страница 4: ...When the trigger is released the trigger gun closes and any further spraying of liquid from the lance is stopped The increase in pressure when the trigger gun is closed causes the unloader valve safet...

Страница 5: ...r with hot water of 60 C raised temperatures occur Do not touch the machine without safety gloves Spray gun with lance No Description Qty Order No 1 Handgriff mit Ventilk rper 1 12 165 2 Abdeckung sei...

Страница 6: ...66 3 Ventilstopfen mit integr Ventil 1 43 067 R1 8 IG 4 Dichtstopfen M 8 x 1 1 13 158 5 O Ring 10 x 2 6 43 068 6 Dichtstopfen M 10 x 1 1 43 043 7 O Ring 1 43 099 8 Kugel 8 5 1 13 148 9 Edelstahlfeder...

Страница 7: ...pay attention to the regulations of your waterworks company In accordance with DIN 1988 the machine may not be directly connected to the public drinking water supply lines A brief connection however i...

Страница 8: ...1 5 Motor Lager B Seite Z Lager 1 43 025 6 Motor Lager A Seite Schulterl 1 43 026 7 Federausgleichsscheibe 1 43 027 8 ldichtung 25 x 35 x 7 1 41 024 9 L fterrad 1 43 028 10 L fterhaube 1 43 029 11 Fla...

Страница 9: ...8 Kunststoffschraube 4 8 x 16 2 43 018 9 Kunststoffschraube 4 8 x 50 5 41 411 10 Kunststoffschraube 5 0 x 120 1 43 309 11 Senkkopfschraube 3 x 45 1 43 020 12 Blechschraube 4 8 x 13 8 44 112 13 Schaum...

Страница 10: ...h pressure hose connected from the machine to the lance The nozzle is blocked No water but the gauge shows full pressure Rinse the hose through first Using the flat spray lance you only have to clean...

Страница 11: ...ter is clean before using your high pressure cleaner Maximum suction hight 1 m A Valve dirty or sticky Pressure gauge does not show full pressure Water comes out in spurts If you do not use the high p...

Страница 12: ...pment lance 90 cm with high pressure nozzle and ST 30 nipple The lance must be aimed when spraying Cleaning cars and all smooth surfaces brush with ST 30 nipple M 22 Rotary point sprayer for extreme s...

Страница 13: ...irect the water jet at the machine itself Rotary scrubbing brush Order No 41 050 1 Underbody lance Order No 41 075 Flat brush Order No 41 073 Dirtkiller Order No 43 094 Environmental refuse disposal w...

Страница 14: ...ts longevity Should it be necessary to change the oil the oil sight glass is to be opened over a reservoir and the machine to be emptied The oil is to be caught in the reservoir and disposed of in the...

Отзывы: