Kramer Electronics Ltd.
WP-20CT
– Technical Specifications
34
Default Communication Parameters
RS-232
Baud Rate:
115,200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII
Example (Set the auto switching timeout to 5 seconds in the event of
5V disable when no input signal is detected):
#AV SW TIMEOUT 4,5<CR>
IP
IP Address:
192.168.1.39
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.39
TCP Port #:
5000
UDP Port #
50000
Default username:
Admin
Default password:
Admin
Full Factory Reset
Embedded Web Pages:
Click
Reset
on the Device Settings > General page.
Default Control and Automation Settings
Ports List
Port Name
Type
Port Properties
Port Description
Comment
CEC-TV
CEC
0
CEC-Broadcast
CEC
15
Local-serial
RS232
2, 9600, 1, None, 8
Local serial port
For custom use
Device-internal
Internal
Actions List
Action Name
Commands List
On Port
Comment
Switch-USB
#ROUTE 1,1,1\x0D
Device-internal
USB web-UI
Switch-HDMI
#ROUTE 1,1,2\x0D
USB web-UI
V-Out-Mute
#VMUTE 1,1\x0D
Display sleep via USB web-UI
V-Out-Unmute
#VMUTE 1,0\x0D
Display wake-up via USB web-UI
A-Out-Volume-Up
#AUD-LVL 1,1,++\x0D
USB web-UI audio output port
action
A-Out-Volume-Down
#AUD-LVL 1,1,--\x0D
A-Out-Mute
#AUD-MUTE 1,1\x0D
A-Out-Unmute
#AUD-MUTE 1,0\x0D
CEC-Power-On
0x04
CEC-TV
CEC-Power-Off
0x36
CEC-Broadcast
Display-Sleep
#VMUTE 1,1\x0D
Device-internal
Display-Wakeup
#VMUTE 1,0\x0D