background image

Kramer Electronics, Ltd. 

 
 
 
 

 

 

 
 
 

Preliminary 

USER MANUAL 

 
 
 

Model: 

VS-88SDI 

 

 

 

Содержание VS-88SDI

Страница 1: ...Kramer Electronics Ltd Preliminary USER MANUAL Model VS 88SDI...

Страница 2: ...ossover Cable 14 6 5 2 Connecting the ETHERNET Port via a Network Hub Straight Through Cable 15 6 6 Configuring the Ethernet Port 15 6 7 Controlling via the Ethernet Port 17 6 8 Using the Ethernet Res...

Страница 3: ...000 Commands 30 11 3 1 Device Initiated Messages 30 11 3 2 Result and Error Codes 30 11 3 3 Basic Routing Commands 30 11 3 4 Preset Commands 31 11 3 5 Operation Commands 31 11 3 6 Machine Information...

Страница 4: ...r 6 Table 3 Machine DIP Switch Settings 11 Table 4 DIP Switch Settings 12 Table 5 Genlock Settings 13 Table 6 VS 88SDI Technical Specifications 21 Table 7 Communication Parameters 22 Table 8 VS 88SDI...

Страница 5: ...er cord2 This user manual and rack ears 3 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review t...

Страница 6: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation...

Страница 7: ...to the bi level or tri level genlock input2 The VS 88SDI is housed in a 19 1U rack mountable enclosure and is fed from a 100 240 VAC universal switching power supply The unit can be controlled via the...

Страница 8: ...influence signal quality and position your Kramer VS 88SDI away from moisture excessive sunlight and dust to avoid interference deterioration in signal quality due to poor matching and elevated noise...

Страница 9: ...Your VS 88SDI 5 Figure 1 VS 88SDI...

Страница 10: ...inate the genlock source 75 or release for looping 14 LOOP BNC Connector Connects to the genlock connector of the next unit in the line 15 INPUT BNC Connectors Connects to the serial digital video sou...

Страница 11: ...s away from the machine This distance can be extended to up to 60 meters when used with three extension cables2 Before using the external IR receiver be sure to arrange for your Kramer dealer to inser...

Страница 12: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the VS 88SDI in a Rack 8 5 Installing the VS 88SDI in a Rack This section provides instructions for rack mounting the 1U unit...

Страница 13: ...4 Optionally2 A genlock source to the GENLOCK BNC connector connect The LOOP BNC connector to the GENLOCK connector of the next unit in the line and release the TERM button for looping3 5 Connect a P...

Страница 14: ...o the VS 88SDI via an RS 232 connection using for example a PC Note that a null modem adapter connection is not required To connect to the VS 88SDI via RS 232 Connect the RS 232 9 pin D sub rear panel...

Страница 15: ...IP SWITCH 1 2 3 4 1 Single or master unit1 OFF ON OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF...

Страница 16: ...ort You can operate the VS 88SDI via the RS 485 port from a distance of up to 1200 meters 3900ft using any device equipped with an RS 485 port for example a PC For successful communication you must se...

Страница 17: ...ing Genlocked Video Signals The genlock feature lets you switch genlocked video signals according to timing of the GENLOCK reference input1 1 Connect the GENLOCK cable 2 To set the genlock timing pres...

Страница 18: ...or identification of the factory default IP address 1 After connecting the Ethernet port configure your PC as follows of the VS 88SDI during the initial configuration 1 Right click the My Network Plac...

Страница 19: ...ct the Ethernet port of the VS 88SDI to the Ethernet port on a network hub or network router via a straight through cable with RJ 45 connectors 6 6 Configuring the Ethernet Port To configure the Ether...

Страница 20: ...he VS 88SDI Select Ethernet if you know the IP address number1 or the machine name The default name for the machine is KRAMER_XXXX2 Serial if you are connected via a serial port 3 Click OK The Device...

Страница 21: ...olling a standalone unit via RS 232 or the Ethernet configure the unit as master Mach No 1 see section 6 1 1 6 8 Using the Ethernet Reset Button To reset Ethernet parameters to the factory defaults 1...

Страница 22: ...ONFIRM modes When the VS 88SDI operates in the AT ONCE mode pressing an OUT IN combination implements the switch immediately In the CONFIRM mode the change does not take place until the TAKE button is...

Страница 23: ...mode when the TAKE button is illuminated do the following 1 Press an OUT IN combination The 7 segment display flashes2 2 Press the TAKE button to confirm the action The 7 segment display stops flashi...

Страница 24: ...key for three seconds The LOCK key illuminates and the front panel keys are inactivated To unlock the front panel press and hold the illuminated LOCK key until the light turns off The front panel keys...

Страница 25: ...m the front panel The IR remote can only set 8 preset configurations equivalent to OUT1 to OUT8 8 Technical Specifications The VS 88SDI technical specifications are shown in Table 6 Table 6 VS 88SDI T...

Страница 26: ...ress and hold Output 1 and Output 3 simultaneously Ethernet Default Settings Reset Settings IP Address 192 168 1 39 Power cycle the unit while holding in the Factory Reset button located on the rear p...

Страница 27: ...cking the desktop icon P3K Wizard The P3K Wizard screen appears1 Figure 8 P3K Wizard Screen 3 Click the Connect button to open the Connect window 1 The screens appearing in this manual are examples of...

Страница 28: ...TECHNOLOGY Using the P3K Wizard 24 Figure 9 Connect Window 4 Choose the appropriate type of connection Ethernet BY IP BY NAME or SERIAL USB and click OK The Connect window disappears and the Device Pr...

Страница 29: ...e white fields as required and click SET 10 2 Updating the VS 88SDI Firmware The VS 88SDI uses a microcontroller that runs firmware located in FLASH memory The latest version of firmware and installat...

Страница 30: ...the front panel buttons or by transmitting protocol commands To switch protocols using the front panel buttons To choose Protocol 2000 press LOCK and OUT 2 at the same time To choose the Protocol 300...

Страница 31: ...er_1 Parameter_2 CR 11 2 1 2 Command String Formal syntax with commands concatenation and addressing Start Address Body Delimiter Destination_id Command_1 Parameter1_1 Parameter1_2 Command_2 Parameter...

Страница 32: ...for K NET K NET Device ID followed by Query sign follows some commands to define a query request Message closing character CR For host messages carriage return ASCII 13 CRLF For machine messages carr...

Страница 33: ...When chaining commands enter the message starting character and the message closing character only once at the beginning of the string and at the end Commands in the string do not execute until the cl...

Страница 34: ...N 1 IN 2 Parameter Description IN Input number or 0 to disconnect output Connection character between in and out parameters OUT Output number or for all outputs Examples Switch video input 2 to output...

Страница 35: ...STO 5CR PRST STR 5 OKCRLF Recall video connections from preset 3 PRCL 3CR PRST RCL 3 OKCRLF Show source of video output 2 from preset 3 PRST VID 3 2CR PRST VID 3 4 2 CRLF 11 3 5 Operation Commands Co...

Страница 36: ...IP_ADDRESS RESULT Read IP address NET IP Short form NTIP NET IP IP_ADDRESS Read MAC address NET MAC Short form NTMC NET MAC MAC_ADDRESS Set subnet mask NET MASK SUBNET_MASK Short form NTMSK NET MASK S...

Страница 37: ...81 IN 2 01 83 88 81 01 83 87 81 01 83 86 81 01 83 85 81 01 83 84 81 01 83 83 81 01 83 82 81 01 83 81 81 IN 3 01 84 88 81 01 84 87 81 01 84 86 81 01 84 85 81 01 84 84 81 01 84 83 81 01 84 82 81 01 84...

Страница 38: ...BYTE Bit 7 Defined as 1 I6 I0 INPUT When switching i e instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly if switching is done via the machine s fr...

Страница 39: ...ber of setups 1 for video 3 for SDI 4 for remote panel 5 for RS 422 controller 14 NOTES on the above table NOTE 1 When the master switcher is reset e g when it is turned on the reset code is sent to t...

Страница 40: ...d the version number would be HEX codes 7D 83 85 81 i e 128dec 3dec for 2nd byte 128dec 5dec for 3rd byte If the OUTPUT is set as 1 then the ASCII coding of the lettering following the machine s name...

Страница 41: ...theractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct claims must bep...

Страница 42: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...