Kramer Electronics Ltd.
VS-88UT
– Technical Specifications
88
Regulatory
Compliance
Safety
CE, UL
Environmental
RoHs, WEEE
Enclosure
Size
19", 19", 2U, rack mountable
Type
Aluminum
Cooling
Fan ventilation
General
Net Dimensions (W, D, H)
43.7cm x 30.6cm x 8.8cm
(17.2" x 12" x 3.5")
Shipping Dimensions (W,
D, H)
52.6cm x 47.5cm x 18.4cm
(20.7" x 18.7" x 7.2")
Net Weight
3.9kg (8.6lbs)
Shipping Weight
5.4kg (11.9lbs) approx.
Accessories
Included
Power cord
Optional
For optimum range and performance use the
recommended USB, Ethernet, serial and IR
Kramer cables available at
www.kramerav.com/product/VS-88UT
Specifications are subject to change without notice at
Default Communication Parameters
RS-232
Protocol 3000
Baud Rate:
115200
Stop Bits:
1
Data Bits:
8
Parity:
None
Example (Set the volume on analog audio
input 5 to 10dB):
#X-AUD-LVL
IN.ANALOG_AUDIO.5.AUDIO.1,10
TCP/IP Parameters
IP Address:
192.168.1.39
UDP Port #:
50000
Subnet mask:
255.255.000.000
Maximum UDP
Connections:
Unlimited
Default gateway:
192.168.0.1
Maximum TCP
Connections:
70 (Web client not
connected)
TCP Port #:
5000
Maximum TCP
Connections:
10 (Web client
connected)
Full Factory Reset
Protocol 3000
Use “
#FACTORY
” command and use “
#RESET
” to restore the factory default
values.