VS-1616D - Protocol 3000
135
16.3.2.2 GEDID
Functions
Permission
Transparency
Set
GEDID
End User
Public
Get
-
-
-
Description
Syntax
Set
Read EDID data from device
#
GEDID
SP
eeprom_id
CR
Get
-
-
Response
Multi-line response:
~nn@
GEDID
SP
eeprom_id,size
CR LF
Edid_dataCR LF
~nn@
GEDID
SP
eeprom_id
SP
OK
CR LF
Parameters
eeprom_id
–
Input
port
EEPROM ID from which to get the EDID:
1-16
(varies according to installed
input cards, see
Section 5.1
size
-
EDID data size sent from the device
Edid_data
– EDID data, as byte stream
Response Trigger
Response is sent to the com port from which the Set (before execution) command was received
Notes
K-Config Example
Read EDID data from a device connected to Input 1:
“#GEDID 1”,0x0D