VP-427X
Quick Start
P/N: 2 9 0 0 - 3 0 1 4 3 1 QS
Rev: 3
Scan for full manual
VP-427X Quick Start Guide
This guide helps you install and use your
VP-427X
for the first time.
Go to
www.kramerav.com/downloads/VP-427X
to download the latest user manual and check if firmware
upgrades are available.
Step 1: Check
what’s in the box
VP-427X
4K HDBT/HDMI Receiver/Scaler
1 Power adapter and cord
1 Quick start guide
1 Bracket set
4 Rubber feet
Step 2: Get to know your VP-427X
#
Feature
Function
1
PROG USB Connector
Connect to a USB stick to perform firmware upgrades.
2
INPUTS
SELECT Button
Press to select the input (HDBT or HDMI).
3
HDBT LED
Lights blue when the HDBT input is selected.
4
HDMI LED
Lights blue when the HDMI input is selected.
5
MENU Button
Press to enter/exit the on-screen display (OSD) menu. Press together with the
– button to reset
the output to 1080p resolution.
6
ENTER Button
In OSD, press to choose the highlighted menu item. Press together with the button
to reset the output to XGA resolution (1024x768).
7
–
In OSD, press to move back through menus or decrement parameter values.
8
Button
In OSD, press to move forward through menus or increment parameter values. When not in
OSD, press to freeze the display.
9
LINK LED
Lights blue when a link is established with the transmitter.
10
ON LED
Lights green when device is powered.
11
INPUTS
HDBT
RJ-45 Connector
Connect to a transmitter (for example, the Kramer
TP-580T
).
12
HDMI Connector
Connect to an HDMI source.
13
OUTPUT
HDMI Connector
Connect to an HDMI acceptor.
14
AUDIO 5-pin Terminal
Block Connector
Connect to a balanced stereo audio acceptor.
15
REMOTE Contact-Closure 4-pin
Terminal Block Connector
Connect to contact closure switches, an occupancy sensor and/or toggle switches (contact
between the desired pin and GND pin), to turn display on or off. See
16
RS-232
CONTROL 3-pin Terminal
Block Connector
Connect to a serial controller or PC.
17
DATA 3-pin Terminal
Block Connector
Connect to a serial data
SOURCE
or acceptor.
18
RELAY 3-pin Terminal Block
Connector
Relay contact pins: normally open (NO), normally closed NC and common (C). Connect to a
device to be controlled by a relay (for example, a motorized projection screen).
19
12V DC Connector
Connect to the supplied power adapter.
Step 3: Mount VP-427X
Install
VP-427X
using one of the following methods:
•
Attach the rubber feet and place the unit on a flat surface.
•
Fasten a bracket (included) on each side of the unit and attach it to a flat surface
(see
www.kramerav.com/downloads/VP-427X
•
Mount the unit in a rack using the recommended rack adapter
(see
www.kramerav.com/product/VP-427X
•
Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
•
Avoid uneven mechanical loading.
•
Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
•
Reliable earthing of rack-mounted equipment should be maintained.
•
Maximum mounting height for the device is 2 meters.