Step 4:  Connect inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

VM-4DKT

 

Wiring the RJ-45 Connectors 

This section defines the DGKAT pinout, using a straight pin-to-pin cable 
with RJ-45 connectors. 

EIA /TIA 568B 

 

PIN 

Wire Color 

 

 

1

 

Orange / White

 

 

The 

ground shielding must be connected/soldered to the 

connector shield.

 

2

 

Orange

 

3

 

Green / White

 

4

 

Blue

 

 

To achieve specified extension distances, use the 
recommended Kramer cables available at 

www.kramerav.com/product/VM-4DKT

. 

Using third-party cables may cause damage! 

5

 

Blue / White

 

6

 

Green

 

7

 

Brown / White

 

8

 

Brown

 

Step 5:  Connect power 

Connect the power adapter to the 

VM-4DKT

 and then plug it into the mains electricity. 

 

Safety Instructions (Se

www.kramerav.com

 for updated safety information)

 

 

Caution: 

  For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual. 

  There are no operator serviceable parts inside the unit. 

Warning: 

  Use only the power cord that is supplied with the unit.  

  Disconnect the power and unplug the unit from the wall before installing.

  

Step 6:  Operate VM-4DKT  

Set the VM-4DKT DIP-switches: 

A DIP-switch that is down is on, up is off. Changes to the DIP-switches take effect immediately. 

Function 

Status 

Active EDID source 

ON (down) 

– Default EDID (default) 

OFF (up) 

– 1st OUT EDID 

EDID auto-acquire 

OFF (up) 

– Auto-acquire enabled (default)  

ON (down) 

– Auto-acquire disabled 

Input HDCP appearance 

OFF (up) 

– Active (default) 

ON (down) 

– Inactive 

Compression setup 

OFF (up) 

– Standard (default) 

ON (down) 

– High 

RS-232 operation mode 

OFF (up) 

– Normal operation mode (default) 

ON (down) 

– Firmware upgrade mode. 

 

Control the devices: 

Operate remotely, by RS-232 serial 
commands transmitted by PC, or 
other serial controller. 

RS-232 Control / Protocol 3000 

Baud Rate:  

115,200 

Parity:  

None 

Data Bits:  

Command Format: 

ASCII 

Stop Bits:  

 

 

Example (get device model name): #model?<cr> 

Factory Default Parameters 

P3K command: 

#factory<cr> 

 

  