Step 3: Mount TP-600TRxr
Install
TP-600TRxr
using one of the following methods:
•
Attach the rubber feet and place the unit on a flat surface.
•
Fasten a bracket (included) on each side of the unit and attach it to a flat surface
www.kramerav.com/downloads/TP-600TRxr
•
Mount the unit in a rack using the recommended rack adapter
www.kramerav.com/product/TP-600TRxr
•
Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
•
Avoid uneven mechanical loading.
•
Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
•
Reliable earthing of rack-mounted equipment should be maintained.
•
Maximum mounting height for the device is 2 meters.
Step 4: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your
TP-600TRxr
extender.
Wiring the RJ-45 Connectors
This section defines the HDBT pinout, using a straight pin-to-pin cable with
RJ-45 connectors.
EIA /TIA 568B
PIN
Wire Color
1
Orange / White
For HDBT cables, it is recommended that the cable ground
shielding be connected/soldered to the connector shield.
2
Orange
3
Green / White
4
Blue
To achieve specified extension distances, use the recommended
Kramer cables available at
. Using third-party cables may cause damage!
5
Blue / White
6
Green
7
Brown / White
8
Brown
Setting the DIP Switches
•
All DIP-switches are set to OFF (up) by default
•
All changes in DIP-Switches apply immediately, on-the-fly (no need to power cycle the device), except for
DIP-switches 1 and 2.
# Feature
DIP-switch Settings
1
Device Operation Mode
OFF (up)
– Receiver mode is active.
ON (down)
– Transmitter mode is active.
2
Active USB Host port
OFF (up)
– Host is active.
ON (down)
– Host is inactive (active on remote paired device).
3
Define IR Pass-through
OFF (up)
– Pass-through the IR signal to or from the IR cable.
ON (down)
– Add IR modulation (38kHz) to the IR output signal (applies only when the IR port is connected
to an IR emitter cable).
4
Programing RS-232
Off (up)
– Normal operation mode is enabled (FW programming RS-232 is inactive).
On (down)
– FW programming RS-232 is active.
Step 5: Connect power
Connect the power cord to
TP-600TRxr
and plug it into the mains electricity.
Safety Instructions (See www.kramerav.com for updated safety information)
Caution:
•
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•
There are no operator serviceable parts inside the unit.
Warning:
•
Use only the power cord that is supplied with the unit.
•
Disconnect the power and unplug the unit from the wall before installing.