TBUS-5xl - Your TBUS-5xl Enclosure 

 

4.1 

TBUS-5xl Optional Inserts 

You can install any wall plate devices as well as any of the single or dual inserts

see our Web site for details. 

4.2 

TBUS-5xl Optional Inner Frames 

The following inner frames can be installed in the 

TBUS-5xl

 enclosure: 

Inner Frames for TBUS-5xl 

Specifications (define what you can include in this 
inner frame): 

 

T5F-1S (P/N: 80-003999) 

 
1 opening for 1 power socket 
1 USB connector 
1 VGA 15-pin HD connector 
1 RJ-45 Ethernet connector 
A 3.5mm mini jack AUDIO connector 

 

T5F-13 (P/N: 80-004099) 

 
1 opening for 1 power socket 
2 blank inserts 
1 cable pass-through insert 
 

 

 

Custom made inner frames can be designed if required. 
Contact Kramer Electronics for more details. 

4.3 

TBUS-5xl Accessories 

Accessories 

Description 

Inserts 

You can install any wall plate devices as well as any of 
the single or dual inserts

—see our Web site for details.  

 

T-2INSERT (P/N: 80-00006699) 

 
The 

T-2INSERT

 kit can be installed inside a single 

power socket opening and includes: 
 
1 single cable pass-through insert  
1 dual cable pass-through insert 

 
 
 
 

i

Содержание TBUS-5XL

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL MODULAR TBUS 5xl Table Connection Bus P N 2900 300070 Rev 3...

Страница 2: ......

Страница 3: ...ling the Inner Frame 11 5 3 Cutting an Opening in the Table 11 5 4 Inserting the TBUS 5xl through the Cut Out Opening 12 5 5 Connecting the Cables 13 5 6 Inserting the Pass through Cables 13 5 7 Adjus...

Страница 4: ...hat are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repea...

Страница 5: ...ng the Best Performance To achieve the best performance Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels oft...

Страница 6: ...omized colors can also be ordered Height adjustment screw holes to set the inner frame ordered separately to the desired height Power socket openings that are suitable for any of the following power s...

Страница 7: ...hen mounting the unit one for each clamp 5 Locking Butterfly Screws Tighten to lock the mounting butterfly screw one for each clamp 6 Mounting Brackets Fit in the bracket slits after inserting the enc...

Страница 8: ...ctor 1 VGA 15 pin HD connector 1 RJ 45 Ethernet connector A 3 5mm mini jack AUDIO connector T5F 13 P N 80 004099 1 opening for 1 power socket 2 blank inserts 1 cable pass through insert Custom made in...

Страница 9: ...oes not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead Not compatible with South African plugs Socket Type Power Specs Socket Type Powe...

Страница 10: ...et USA TS 2US 80 001999 100 125V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Belgium and France TS 2FR 80 002299 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Germany and EU TS 2DE 80 002...

Страница 11: ...d Options You can order any of the following power cords to use with a modular TBUS Power Cord Type Description P N 6ft 110V North America C AC US 110V 91 000099 6ft 125V Japan C AC JP 125V 91 000699...

Страница 12: ...gh the opening and secure to the table see Section 5 4 5 Connect the cables see Section 5 5 6 Insert the pass through cables see Section 5 6 7 Adjust the height of the inner frame see Section 5 7 5 1...

Страница 13: ...plate 2 Place the required Kramer insert over the opening insert the two screws to fix the Kramer insert in place and tighten them Figure 3 TBUS 5xl Inner Frame P N 80 004099 Feature Function 1 Blank...

Страница 14: ...nstructions 5 3 Cutting an Opening in the Table To cut an opening in the table 1 Place the included cut out template that is included with your TBUS 5xl on the surface of the table exactly where you w...

Страница 15: ...d from around the outer rim of the TBUS 5xl housing Beware of the sharp edge 2 Carefully insert the unit into the prepared opening see Figure 5 3 Take the support brackets under the table and place th...

Страница 16: ...the Pass through Cables When replacing a blank insert with the pass through insert for example to connect a laptop do the following 1 Remove the two screws attaching the split pass through bracket 2...

Страница 17: ...djust the inner frame heights to accommodate large or bulky cables To adjust perform the following 1 Remove the height adjustment screws while supporting the surface from underneath with your fingers...

Страница 18: ...Using the TBUS 5xl Once the TBUS 5xl is installed you can easily customize it to suit your own requirements by plugging in the required A V equipment as illustrated in the example in Figure 6 Figure 6...

Страница 19: ...m and France 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Italy 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Australia 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Israel 220V AC 50...

Страница 20: ......

Страница 21: ...s visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerav com E mail info kramerel com P N 2900 300070 Rev 3 SAFETY WARN...

Отзывы: