background image

Kramer Electronics Ltd. 

 

PA-120Net, PA-240Net 

– Using the Embedded Web Pages 

15 

 

Setting the Line Level Output Parameters 

PA-240Net

 can automatically set the line level output parameters according to the speaker 

output parameters (see 

Setting the Speaker Output Parameters

 on page 

13

), or they can be 

set manually via the Line Level Output page. 

To set the line level output parameters independently (unlinked to speaker output 
parameters): 

1.  In the Navigation pane, click 

Speaker Output

. The Speaker Output page appears. 

2.  Click 

Unlinked

3.  In the Navigation pane, click 

Line Level Output

. The Line Level Output page appears. 

 

Figure 11: Line Level Output Page 

4.  Set the line level parameters (see 

Setting the Speaker Output Parameters

 on pag

13

)

Содержание PA-120Net

Страница 1: ...P N 2900 301040 Rev 2 www KramerAV com USER MANUAL MODEL PA 240Net 240W Power Amplifier PA 120Net 120W Power Amplifier...

Страница 2: ...ing PA 240Net via the Ethernet Port 9 Operating the PA 240Net 11 Setting the DIP Switches 11 Adjusting the Master Volume 11 Using the Embedded Web Pages 12 Setting the Speaker Output Parameters 13 Set...

Страница 3: ...Achieving the Best Performance Use only good quality connection cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor mat...

Страница 4: ...240Net it refers to both PA 240Net and PA 120Net unless specified otherwise PA 240Net is a high performance Hi Z 70V 100V and Lo Z 4 8 network controllable power amplifier featuring balanced unbalance...

Страница 5: ...the device shuts down until correct operational conditions are regained Dante LED indicator for Dante network availability Digital audio normal operation LED Auto standby with adjustable threshold Con...

Страница 6: ...s red when the speaker output is muted off when unmuted CLIP LED Lights red when the signal is clipped on the output and creating distortion When clipping is detected lower the volume until the LED tu...

Страница 7: ...rotate to set the maximum amplifier volume ETHERNET RJ 45 Connector Connect to an ETHERNET LAN to control the PA 240Net via built in web page By default IP is fixed at 192 168 1 39 RS 232 G Tx Rx Port...

Страница 8: ...follows For Hi Z connection connect Hi Z and COM terminal blocks to the and terminals of a mono speaker for example the Galil 8 C ceiling speakers daisy chained The speakers either output the left sid...

Страница 9: ...el Connecting the Output to a Balanced Unbalanced Stereo Audio Acceptor The following are the pinouts for connecting the output to a balanced or unbalanced stereo audio acceptor Figure 2 Connecting th...

Страница 10: ...Connecting an unbalanced stereo audio source to the balanced input Connecting to PA 240Net via RS 232 You can connect to the PA 240Net via an RS 232 connection using for example a PC From the RS 232 9...

Страница 11: ...tion instructions Connecting the Ethernet Port Directly to a PC You can connect the Ethernet port of the PA 240Net directly to the Ethernet port on your PC using a crossover cable with RJ 45 connector...

Страница 12: ...our IT system appears as shown in Figure 7 or Figure 8 Figure 7 Internet Protocol Version 4 Properties Window Figure 8 Internet Protocol Version 6 Properties Window 6 Select Use the following IP Addre...

Страница 13: ...n describes the following operations Setting the DIP Switches on page 11 Adjusting the Master Volume on page 11 Setting the DIP Switches By default the DIP switches are set to Hi Z and 100V DIP Switch...

Страница 14: ...FireFox Chrome Mac iOS Safari Android Chrome The PA 240Net web pages enable performing the following Setting the Speaker Output Parameters on page 13 Setting the Line Level Output Parameters on page...

Страница 15: ...hide the navigation list Setting the Speaker Output Parameters Use the Speaker Output page to set the speaker input signals mixing and the output parameters PA 240Net can automatically set the line le...

Страница 16: ...frequencies then the Q and finally the Bass Mid and Treble ranges To set EQ levels 1 In the navigation pane click Speaker Output The Speaker Output page appears 2 In the EQ column set the following Fr...

Страница 17: ...ers on page 13 or they can be set manually via the Line Level Output page To set the line level output parameters independently unlinked to speaker output parameters 1 In the Navigation pane click Spe...

Страница 18: ...to reduce the stereo input to mono Changing Standby Settings To change standby settings 1 In the Navigation pane click Audio Settings The Audio Settings page appears see Figure 12 2 Define the Standb...

Страница 19: ...ons Changing the name of the unit by typing the name in the Unit name text box Changing the Ethernet Controller Ethernet Dante Settings on page 17 Saving and Loading Settings on page 18 Performing a F...

Страница 20: ...wing message appears Configuration file is ready right click here to download 3 Right click the link right click here and click Save link as The configuration is downloaded to your PC To load a config...

Страница 21: ...assword 1 In the Navigation pane click Security The Authentication page appears see Figure 14 Figure 14 Authentication Page 2 Set Activate Security to Disabled A message prompting for your password ap...

Страница 22: ...uthentication is required to access web pages Figure 15 Password Settings Page Security Log In 4 Type the User Name Admin by default and Password Admin by default 5 Click Log In 6 Select Security from...

Страница 23: ...ion from Audinate Use the controller to route audio and configure devices on a Dante network It features automatic device discovery one click signal routing and user editable device and channel labels...

Страница 24: ...dio THD Noise THD N 1kHz 1W 0 003 Audio 2nd Harmonic 0 08 75W RMS 4 6 67kHz Controls Output volume attenuator IP and RS 232 Power Source Universal mains operational voltage 85V AC 265V AC Universal ma...

Страница 25: ...VL 1 2 10 TCP IP Parameters Ethernet Controller Ethernet Dante IP Address 192 168 1 39 DHCP Subnet Mask 255 255 000 000 N A Default Gateway 192 168 0 1 N A Maximum UDP Connections Unlimited N A Maximu...

Страница 26: ...ming of the command varies according to the terminal communication software K Touch Builder Kramer software K Config Kramer configuration software All the examples provided in this section are based o...

Страница 27: ...message closing character A string can contain more than one command Commands are separated by a pipe character Message starting character For host command query For device response Device address K N...

Страница 28: ...ge Format Start Address optional Body Delimiter Device_id Message CR Simple Command Command string with only one command without addressing Start Body Delimiter Command SP Parameter_1 Parameter_2 CR C...

Страница 29: ...Get device build date FACTORY Reset to factory default configuration HELP Get command list MODEL Get device model PROT VER Get device protocol version RESET Reset device SN Get device serial number NA...

Страница 30: ...n FACTORYCR Get Response nn FACTORYSPOKCR LF Notes This command deletes all user data from the device The deletion can take some time Your device may require powering off and powering on for the chang...

Страница 31: ...uests K Config Example MODEL 0x0D PROT VER Functions Permission Transparency Set Get PROT VER End User Public Description Syntax Set Get Get device protocol version PROT VER CR Response nn PROT VERSP3...

Страница 32: ...nistrator Public Get NAME End User Public Description Syntax Set Set machine DNS name NAMESPmachine_nameCR Get Get machine DNS name NAME CR Response Set nn NAMESPmachine_nameCR LF Get nn NAME SPmachin...

Страница 33: ...tandby mode state BALANCE Set get balance level EQ FREQ Set get equalizer center EQ LVL Set get equalization level EQ Q Set get Q level MUTE Set get audio mute AUD CH LINK Functions Permission Transpa...

Страница 34: ...ssion Transparency Set AUD FILTER End User Public Get AUD FILTER End User Public Description Syntax Set Set filter AUD FILTERSPChannel FilterType Freq StateCR Get Get filter state AUD FILTER SPChannel...

Страница 35: ...nfig Example Set the line level output to Hi Z and 70V AUD HI Z 2 1 0 0x0D AUD IN CONF Functions Permission Transparency Set AUD IN CONF End User Public Get AUD IN CONF End User Public Description Syn...

Страница 36: ...10dB mutebehavior optional 1 changing the volume does not affect the mute state K Config Example Set the speaker output audio level t0 50dB AUD LVL 1 1 50 0x0D AUD MIX Functions Permission Transparen...

Страница 37: ...o the right and play both Notes These commands are active only when the state is HI Z otherwise an error is returned To set the MonoMode parameter must be used K Config Example Set the output to mix t...

Страница 38: ...andby mode Notes Active only in auto mode K Config Example Set the standby delay time to 10 minutes AUD STANDBY 1 10 0x0D BALANCE Functions Permission Transparency Set BALANCE End User Public Get BALA...

Страница 39: ...1kHz B 80Hz 2 T 15kHz M 1 5kHz B 500Hz 3 T 17 5kHz M 2 5kHz B 200Hz Notes T Treble M Middle B Bass K Config Example Set speaker output equalizer frequency on the bass to 200Hz EQ FREQ 1 1 0 3 0x0D EQ...

Страница 40: ...output 2 Line level output EqType 0 Bass 1 Middle 2 Treble Q_level 0 to 15 Q level K Config Example Set the line level output treble Q level to 8 EQ Q 1 2 8 4 0x0D MUTE Functions Permission Transpare...

Страница 41: ...LF Parameters id network ID ip network IP net_mask network mask gateway network gateway K Config Example NET CONFIG 1 192 168 113 10 255 255 0 0 192 168 0 1 0x0D ETH PORT Functions Permission Transpa...

Страница 42: ...ting Ethernet to devices with DHCP may take more time in some networks To connect with a randomly assigned IP by DHCP specify the device DNS name if available using the command NAME You can also get a...

Страница 43: ...y you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of...

Страница 44: ...RNING Disconnect the unit from the power supply before opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user m...