Setting Analog In Trigger Parameters
Figure 17: GPIO Port Settings Page Analog IN
Set the trigger type to Analog In. With this selection, the port is triggered by an analog
external device, such as, a volume control device. The trigger is activated once when the
detected voltage is within 0 to 30V DC voltage range.
You can select the number of steps the analog input signal will be divided into, starting with
step 1 and with a maximum of 100 (default 8). The voltage of each step is dependent on the
number of steps selected:
Individual step voltage = 30V / number of steps
When selecting the Analog In trigger type, the Pullup resistor and Threshold settings are
disabled.
Setting Relay Port Status
The Relay Port Settings page allows you to turn the relays on and off to control relay-driven
devices such as shades, projection screens and lighting systems.
Figure 18: Relay Port Settings Page