background image

Kramer Electronics, Ltd. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER MANUAL 

 

 

Model: 

FC-4002 

Format Converter / TBC 

 

 

Содержание FC-4002

Страница 1: ...Kramer Electronics Ltd USER MANUAL Model FC 4002 Format Converter TBC...

Страница 2: ...rter TBC 3 Figure 2 Connecting a PC without using a Null modem Adapter 7 Figure 3 Connecting the FC 4002 Format Converter TBC 8 Tables Table 1 Front Panel FC 4002 Format Converter TBC 4 Table 2 Rear P...

Страница 3: ...you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resolution c...

Страница 4: ...el buttons for input selection CV Y C YUV and RGB S Genlock freeze and panel lock Coarse trimmers and fine trimmers for adjusting the sync phase and the horizontal to subcarrier phase SCH Control via...

Страница 5: ...Your FC 4002 Format Converter TBC 3 Figure 1 FC 4002 Format Converter TBC...

Страница 6: ...lock source 75 or release for looping 3 16 CV BNC Connector Connects to the composite video source 17 Y C 4p Connector Connects to the s Video Y C source 18 G Y BNC Connector 19 R R Y BNC Connector 20...

Страница 7: ...Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connec...

Страница 8: ...3 Connect the four BNC OUTPUT connectors CV R R Y G Y and C B B Y and SYNC to a video acceptor for example a plasma display 4 Connect the LOOP BNC connector to the next FC 4002 Genlocked unit if requi...

Страница 9: ...your PC to the RS 232 DB9 rear panel port on the FC 4002 unit as Figure 2 illustrates Figure 2 Connecting a PC without using a Null modem Adapter 6 2 Dipswitch Settings The FC 4002 dipswitch settings...

Страница 10: ...IP 5 Dipswitch Set as follows 4 AGC ON for enabling automatic gain control OFF for disabling automatic gain control 5 75 Bar Generator ON for enabling 75 Bar Generator OFF for disabling 75 Bar Generat...

Страница 11: ...SCH phase SYNC phase H shift freeze panel lock POWER SOURCE 100 240VAC 50 60Hz 14VA DIMENSIONS 19 inch W 7 inch D 1U H rack mountable WEIGHT 2 6 kg 5 7 lbs approx ACCESSORIES Power cord Null modem Ad...

Страница 12: ...the machine or 1 when sending from the machine to the PC Table 8 Instruction Set INSTRUCTION I5 I4 I3 I2 I1 I0 0 Reset 0 0 0 0 0 0 16 Error 0 1 0 0 0 0 32 Read front panel switch data 1 0 0 0 0 0 33...

Страница 13: ...version number before the decimal point and EXTENDED DATA is the value following the decimal point For example for version 3 4 the machine replies with DATA 03 hex and EXTENDED DATA 04 hex FRONT PANEL...

Страница 14: ...is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Страница 15: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Отзывы: