![KRAL DKC Series Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/kral/dkc-series/dkc-series_operating-instructions-manual_2000370025.webp)
8 Installation, removal
8.6 Removing the pump station
8.5.3
Installing the fluid heating system
Personnel qualification:
o
Fitter
Personal protective equipment:
o
Work clothing
o
Protective gloves
o
Safety boots
1.
Remove the upper and lower screw plug of the heating duct.
1
2
2.
Small pump station
: Mount the piping
2
with the inserted screw connection
1
.
1
2
3
3
3.
Large pump station
: Mount the piping
2
with the inserted screw connection
1
and the swivel in-
serted screw connection
3
.
8.5.4
Installing the heating system special design
When installing special designs contact the manufacturer.
8.6 Removing the pump station
Personnel qualification:
o
Transport personnel
o
Fitter
o
Electrician
Personal protective equipment:
o
Work clothing
o
Protective helmet
o
Protective gloves
o
Safety boots
Aids:
o
Mobile crane, forklift, hoisting equipment
o
Collection tank
DANGER
Risk of death resulting from electric shock.
► Ensure that the electrical power supply is de-energized and is secured against being switched
back on.
► Observe the operating instructions of the electrical components.
Operating instructions
OID 02en-GB Edition 2019-11
25